EHRS-FM IG

ISO/HL7 10781 - Electronic Health Record System Functional Model, Release 2.1
0.14.0 - CI Build

ISO/HL7 10781 - Electronic Health Record System Functional Model, Release 2.1 - Local Development build (v0.14.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions

: RI.1.1.8 Transmit Record Lifecycle Event (Function) - XML Representation

Active as of 2024-06-01

Raw xml | Download



<Requirements xmlns="http://hl7.org/fhir">
  <id value="EHRSFMR2.1-RI.1.1.8"/>
  <meta>
    <profile value="http://hl7.org/ehrs/StructureDefinition/FMFunction"/>
  </meta>
  <text>
    <status value="extensions"/>
    <div xmlns="http://www.w3.org/1999/xhtml">
    <span id="description"><b>Statement <a href="https://hl7.org/fhir/versions.html#std-process" title="Normative Content" class="normative-flag">N</a>:</b> <div><p>Transmit Record Entries (1 or more instances)</p>
</div></span>

    
    <span id="purpose"><b>Description <a href="https://hl7.org/fhir/versions.html#std-process" title="Informative Content" class="informative-flag">I</a>:</b> <div><p>Occurs when an agent causes the system to send record entry content from one (EHR/PHR/other) system to another.</p>
<p>Reference: ISO 21089-2018, Section 15.8.</p>
</div></span>
    

    

    
    <span id="requirements"><b>Criteria <a href="https://hl7.org/fhir/versions.html#std-process" title="Normative Content" class="normative-flag">N</a>:</b></span>
    
    <table id="statements" class="grid dict">
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>RI.1.1.8#01</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                
                
                <span>SHOULD</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>The system SHOULD provide the ability to transmit Record Entry content to external systems, retaining original, unaltered content and signature bindings, Action and Record Entry provenance and metadata.</p>
</div></span>
                
                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>RI.1.1.8#02</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                
                
                <span>SHALL</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>The system SHALL provide the ability to transmit Record Entry extracts to external systems, including content, context, provenance and metadata.</p>
</div></span>
                
                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>RI.1.1.8#03</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                
                
                <span>SHALL</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>The system SHALL provide the ability to capture the identity of the patient or individual subject to whom Record Entry content was transmitted.</p>
</div></span>
                
                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>RI.1.1.8#04</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                <i>dependent</i>
                
                
                <i>conditional</i>
                
                
                <span>SHOULD</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>IF a specific recipient is known, THEN the system SHOULD transmit protected Record Entry content based on established permissions and according to scope of practice, organizational policy, and/or jurisdictional law.</p>
</div></span>
                
                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>RI.1.1.8#05</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                
                <i>conditional</i>
                
                
                <span>SHOULD</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>IF known and explicit as to Record Entry content being transmitted, THEN the system SHOULD transmit corresponding authorizations and patient consent permissions.</p>
</div></span>
                
                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>RI.1.1.8#06</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                
                
                <span>SHALL</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>The system SHALL conform to function [[TI.1.6]] (Secure Data Exchange).</p>
</div></span>
                
                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>RI.1.1.8#07</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                
                
                <span>SHALL</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>The system SHALL provide the ability to extract Record Entry content prior to transmittal, conforming to function [[RI.1.1.13]] (Extract Record Entry Content).</p>
</div></span>
                
                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>RI.1.1.8#08</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                
                
                <span>SHALL</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>The system SHALL provide the ability to de-identify Record Entry content prior to transmittal, conforming to function [[RI.1.1.10]] (De-Identify Record Entries).</p>
</div></span>
                
                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>RI.1.1.8#09</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                <i>dependent</i>
                
                
                
                <span>SHALL</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>The system SHALL provide the ability to transmit updates (new versions) of Record Entry Content to known recipients of prior versions according to scope of practice, organizational policy, and/or jurisdictional law.</p>
</div></span>
                
                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>RI.1.1.8#10</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                <i>dependent</i>
                
                
                
                <span>SHALL</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>The system SHALL provide the ability to transmit with each exchange the most recent or all versions of Record Entry Content according to scope of practice, organizational policy, and/or jurisdictional law.</p>
</div></span>
                
                
            </td>
        </tr>
        
    </table>
</div>
  </text>
  <url value="http://hl7.org/ehrs/Requirements/EHRSFMR2.1-RI.1.1.8"/>
  <version value="0.14.0"/>
  <name value="RI_1_1_8_Transmit_Record_Lifecycle_Event"/>
  <title value="RI.1.1.8 Transmit Record Lifecycle Event (Function)"/>
  <status value="active"/>
  <date value="2024-06-01T08:34:10+00:00"/>
  <publisher value="EHR WG"/>
  <contact>
    <telecom>
      <system value="url"/>
      <value value="http://www.hl7.org/Special/committees/ehr"/>
    </telecom>
  </contact>
  <description value="Transmit Record Entries (1 or more instances)"/>
  <purpose
           value="Occurs when an agent causes the system to send record entry content from one (EHR/PHR/other) system to another.  

Reference: ISO 21089-2018, Section 15.8."/>
  <statement>
    <extension
               url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="EHRSFMR2.1-RI.1.1.8-01"/>
    <label value="RI.1.1.8#01"/>
    <conformance value="SHOULD"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHOULD provide the ability to transmit Record Entry content to external systems, retaining original, unaltered content and signature bindings, Action and Record Entry provenance and metadata."/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="EHRSFMR2.1-RI.1.1.8-02"/>
    <label value="RI.1.1.8#02"/>
    <conformance value="SHALL"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHALL provide the ability to transmit Record Entry extracts to external systems, including content, context, provenance and metadata."/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="EHRSFMR2.1-RI.1.1.8-03"/>
    <label value="RI.1.1.8#03"/>
    <conformance value="SHALL"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHALL provide the ability to capture the identity of the patient or individual subject to whom Record Entry content was transmitted."/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
      <valueBoolean value="true"/>
    </extension>
    <key value="EHRSFMR2.1-RI.1.1.8-04"/>
    <label value="RI.1.1.8#04"/>
    <conformance value="SHOULD"/>
    <conditionality value="true"/>
    <requirement
                 value="IF a specific recipient is known, THEN the system SHOULD transmit protected Record Entry content based on established permissions and according to scope of practice, organizational policy, and/or jurisdictional law."/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="EHRSFMR2.1-RI.1.1.8-05"/>
    <label value="RI.1.1.8#05"/>
    <conformance value="SHOULD"/>
    <conditionality value="true"/>
    <requirement
                 value="IF known and explicit as to Record Entry content being transmitted, THEN the system SHOULD transmit corresponding authorizations and patient consent permissions."/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="EHRSFMR2.1-RI.1.1.8-06"/>
    <label value="RI.1.1.8#06"/>
    <conformance value="SHALL"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHALL conform to function [[TI.1.6]] (Secure Data Exchange)."/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="EHRSFMR2.1-RI.1.1.8-07"/>
    <label value="RI.1.1.8#07"/>
    <conformance value="SHALL"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHALL provide the ability to extract Record Entry content prior to transmittal, conforming to function [[RI.1.1.13]] (Extract Record Entry Content)."/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="EHRSFMR2.1-RI.1.1.8-08"/>
    <label value="RI.1.1.8#08"/>
    <conformance value="SHALL"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHALL provide the ability to de-identify Record Entry content prior to transmittal, conforming to function [[RI.1.1.10]] (De-Identify Record Entries)."/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
      <valueBoolean value="true"/>
    </extension>
    <key value="EHRSFMR2.1-RI.1.1.8-09"/>
    <label value="RI.1.1.8#09"/>
    <conformance value="SHALL"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHALL provide the ability to transmit updates (new versions) of Record Entry Content to known recipients of prior versions according to scope of practice, organizational policy, and/or jurisdictional law."/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
      <valueBoolean value="true"/>
    </extension>
    <key value="EHRSFMR2.1-RI.1.1.8-10"/>
    <label value="RI.1.1.8#10"/>
    <conformance value="SHALL"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHALL provide the ability to transmit with each exchange the most recent or all versions of Record Entry Content according to scope of practice, organizational policy, and/or jurisdictional law."/>
  </statement>
</Requirements>