ISO/HL7 10781 - Electronic Health Record System Functional Model, Release 2.1
0.14.0 - CI Build
ISO/HL7 10781 - Electronic Health Record System Functional Model, Release 2.1 - Local Development build (v0.14.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions
Active as of 2024-06-01 |
Transmit Record Entries (1 or more instances)
Occurs when an agent causes the system to send record entry content from one (EHR/PHR/other) system to another.
Reference: ISO 21089-2018, Section 15.8.
RI.1.1.8#01 | SHOULD |
The system SHOULD provide the ability to transmit Record Entry content to external systems, retaining original, unaltered content and signature bindings, Action and Record Entry provenance and metadata. |
RI.1.1.8#02 | SHALL |
The system SHALL provide the ability to transmit Record Entry extracts to external systems, including content, context, provenance and metadata. |
RI.1.1.8#03 | SHALL |
The system SHALL provide the ability to capture the identity of the patient or individual subject to whom Record Entry content was transmitted. |
RI.1.1.8#04 | dependent conditional SHOULD |
IF a specific recipient is known, THEN the system SHOULD transmit protected Record Entry content based on established permissions and according to scope of practice, organizational policy, and/or jurisdictional law. |
RI.1.1.8#05 | conditional SHOULD |
IF known and explicit as to Record Entry content being transmitted, THEN the system SHOULD transmit corresponding authorizations and patient consent permissions. |
RI.1.1.8#06 | SHALL |
The system SHALL conform to function [[TI.1.6]] (Secure Data Exchange). |
RI.1.1.8#07 | SHALL |
The system SHALL provide the ability to extract Record Entry content prior to transmittal, conforming to function [[RI.1.1.13]] (Extract Record Entry Content). |
RI.1.1.8#08 | SHALL |
The system SHALL provide the ability to de-identify Record Entry content prior to transmittal, conforming to function [[RI.1.1.10]] (De-Identify Record Entries). |
RI.1.1.8#09 | dependent SHALL |
The system SHALL provide the ability to transmit updates (new versions) of Record Entry Content to known recipients of prior versions according to scope of practice, organizational policy, and/or jurisdictional law. |
RI.1.1.8#10 | dependent SHALL |
The system SHALL provide the ability to transmit with each exchange the most recent or all versions of Record Entry Content according to scope of practice, organizational policy, and/or jurisdictional law. |