Example Requirements: RI.1.1.9 Receive/Retain Record Lifecycle Event (Function)

Active as of 2024-01-31
RI.1.1.9#01 SHOULD

The system SHOULD provide the ability to capture and maintain Record Entry content from external systems, retaining and persisting original unaltered content and signature bindings, Action and Record Entry provenance and metadata.

RI.1.1.9#02 SHALL

The system SHALL provide the ability to capture and maintain Record Entry extracts from external systems, retaining and persisting source, identity, record content, corresponding provenance and metadata.

RI.1.1.9#03 SHALL

The system SHALL provide the ability to capture the identity of the patient or individual subject to whom Record Entry content was received.

RI.1.1.9#04 SHOULD

IF received with Record Entry content, THEN the system SHOULD control subsequent data access to that permitted by corresponding authorizations and patient consents.