EHRS-FM IG

ISO/HL7 10781 - Electronic Health Record System Functional Model, Release 2.1
0.14.0 - CI Build

ISO/HL7 10781 - Electronic Health Record System Functional Model, Release 2.1 - Local Development build (v0.14.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions

: TI.2.1 Audit Triggers (Function) - TTL Representation

Active as of 2024-06-01

Raw ttl | Download


@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

 a fhir:Requirements ;
  fhir:nodeRole fhir:treeRoot ;
  fhir:id [ fhir:v "EHRSFMR2.1-TI.2.1"] ; # 
  fhir:meta [
    ( fhir:profile [
fhir:v "http://hl7.org/ehrs/StructureDefinition/FMFunction"^^xsd:anyURI ;
fhir:link <http://hl7.org/ehrs/StructureDefinition/FMFunction>     ] )
  ] ; # 
  fhir:text [
fhir:status [ fhir:v "extensions" ] ;
fhir:div "<div xmlns=\"http://www.w3.org/1999/xhtml\">\n    <span id=\"description\"><b>Statement <a href=\"https://hl7.org/fhir/versions.html#std-process\" title=\"Normative Content\" class=\"normative-flag\">N</a>:</b> <div><p>Manage Audit Triggers</p>\n</div></span>\n\n    \n    <span id=\"purpose\"><b>Description <a href=\"https://hl7.org/fhir/versions.html#std-process\" title=\"Informative Content\" class=\"informative-flag\">I</a>:</b> <div><p>EHR Systems have built in audit triggers to capture key events in real-time. Audit triggers signal key:</p>\n<ul>\n<li>Record management and lifecycle events;</li>\n<li>Security events related to system and data safeguards, both routine and exceptional;</li>\n<li>System events related to performance and operations, both routine and exceptional.</li>\n<li>Clinical events with special log requirements.</li>\n</ul>\n</div></span>\n    \n\n    \n\n    \n    <span id=\"requirements\"><b>Criteria <a href=\"https://hl7.org/fhir/versions.html#std-process\" title=\"Normative Content\" class=\"normative-flag\">N</a>:</b></span>\n    \n    <table id=\"statements\" class=\"grid dict\">\n        \n        <tr>\n            <td style=\"padding-left: 4px;\">\n                \n                <span>TI.2.1#01</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\">\n                \n                <i>dependent</i>\n                \n                \n                \n                <span>SHALL</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\" class=\"requirement\">\n                \n                <span><div><p>The system SHALL audit key events, as specified in function [[TI.2.1]] (Audit Triggers) and child functions, according to scope of practice, organizational policy, and/or jurisdictional law.</p>\n</div></span>\n                \n                \n            </td>\n        </tr>\n        \n        <tr>\n            <td style=\"padding-left: 4px;\">\n                \n                <span>TI.2.1#02</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\">\n                \n                <i>dependent</i>\n                \n                \n                \n                <span>SHALL</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\" class=\"requirement\">\n                \n                <span><div><p>The system SHALL capture key Audit Metadata at each Audit Trigger, as specified in [[TI.2.1]] (Audit Triggers) and child functions, according to scope of practice, organizational policy, and/or jurisdictional law.</p>\n</div></span>\n                \n                \n            </td>\n        </tr>\n        \n        <tr>\n            <td style=\"padding-left: 4px;\">\n                \n                <span>TI.2.1#03</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\">\n                \n                <i>dependent</i>\n                \n                \n                \n                <span>SHALL</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\" class=\"requirement\">\n                \n                <span><div><p>The system SHALL capture an Audit Log Entry at each Audit Trigger as specified in [[TI.2.1]] (Audit Triggers) according to scope of practice, organizational policy, and/or jurisdictional law.</p>\n</div></span>\n                \n                \n            </td>\n        </tr>\n        \n        <tr>\n            <td style=\"padding-left: 4px;\">\n                \n                <span>TI.2.1#04</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\">\n                \n                \n                \n                <span>SHALL</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\" class=\"requirement\">\n                \n                <span><div><p>The system SHALL capture the current master clock time to establish valid record date and time metadata.</p>\n</div></span>\n                \n                \n            </td>\n        </tr>\n        \n        <tr>\n            <td style=\"padding-left: 4px;\">\n                \n                <span>TI.2.1#05</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\">\n                \n                \n                \n                <span>MAY</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\" class=\"requirement\">\n                \n                <span><div><p>The system MAY manage Audit Trigger logging using a common audit engine (e.g., using schema and transports such as specified in the Audit Log specification of IHE Audit Trails and Node Authentication (ATNA) Profile).</p>\n</div></span>\n                \n                \n            </td>\n        </tr>\n        \n    </table>\n</div>"
  ] ; # 
  fhir:url [ fhir:v "http://hl7.org/ehrs/Requirements/EHRSFMR2.1-TI.2.1"^^xsd:anyURI] ; # 
  fhir:version [ fhir:v "0.14.0"] ; # 
  fhir:name [ fhir:v "TI_2_1_Audit_Triggers"] ; # 
  fhir:title [ fhir:v "TI.2.1 Audit Triggers (Function)"] ; # 
  fhir:status [ fhir:v "active"] ; # 
  fhir:date [ fhir:v "2024-06-01T08:34:10+00:00"^^xsd:dateTime] ; # 
  fhir:publisher [ fhir:v "EHR WG"] ; # 
  fhir:contact ( [
    ( fhir:telecom [
fhir:system [ fhir:v "url" ] ;
fhir:value [ fhir:v "http://www.hl7.org/Special/committees/ehr" ]     ] )
  ] ) ; # 
  fhir:description [ fhir:v "Manage Audit Triggers"] ; # 
  fhir:purpose [ fhir:v "EHR Systems have built in audit triggers to capture key events in real-time. Audit triggers signal key:\n- Record management and lifecycle events;\n- Security events related to system and data safeguards, both routine and exceptional;\n- System events related to performance and operations, both routine and exceptional.\n- Clinical events with special log requirements."] ; # 
  fhir:statement ( [
    ( fhir:extension [
fhir:url [ fhir:v "http://hl7.org/ehrs/StructureDefinition/requirements-dependent"^^xsd:anyURI ] ;
fhir:value [ fhir:v "true"^^xsd:boolean ]     ] ) ;
fhir:key [ fhir:v "EHRSFMR2.1-TI.2.1-01" ] ;
fhir:label [ fhir:v "TI.2.1#01" ] ;
    ( fhir:conformance [ fhir:v "SHALL" ] ) ;
fhir:conditionality [ fhir:v "false"^^xsd:boolean ] ;
fhir:requirement [ fhir:v "The system SHALL audit key events, as specified in function [[TI.2.1]] (Audit Triggers) and child functions, according to scope of practice, organizational policy, and/or jurisdictional law." ]
  ] [
    ( fhir:extension [
fhir:url [ fhir:v "http://hl7.org/ehrs/StructureDefinition/requirements-dependent"^^xsd:anyURI ] ;
fhir:value [ fhir:v "true"^^xsd:boolean ]     ] ) ;
fhir:key [ fhir:v "EHRSFMR2.1-TI.2.1-02" ] ;
fhir:label [ fhir:v "TI.2.1#02" ] ;
    ( fhir:conformance [ fhir:v "SHALL" ] ) ;
fhir:conditionality [ fhir:v "false"^^xsd:boolean ] ;
fhir:requirement [ fhir:v "The system SHALL capture key Audit Metadata at each Audit Trigger, as specified in [[TI.2.1]] (Audit Triggers) and child functions, according to scope of practice, organizational policy, and/or jurisdictional law." ]
  ] [
    ( fhir:extension [
fhir:url [ fhir:v "http://hl7.org/ehrs/StructureDefinition/requirements-dependent"^^xsd:anyURI ] ;
fhir:value [ fhir:v "true"^^xsd:boolean ]     ] ) ;
fhir:key [ fhir:v "EHRSFMR2.1-TI.2.1-03" ] ;
fhir:label [ fhir:v "TI.2.1#03" ] ;
    ( fhir:conformance [ fhir:v "SHALL" ] ) ;
fhir:conditionality [ fhir:v "false"^^xsd:boolean ] ;
fhir:requirement [ fhir:v "The system SHALL capture an Audit Log Entry at each Audit Trigger as specified in [[TI.2.1]] (Audit Triggers) according to scope of practice, organizational policy, and/or jurisdictional law." ]
  ] [
    ( fhir:extension [
fhir:url [ fhir:v "http://hl7.org/ehrs/StructureDefinition/requirements-dependent"^^xsd:anyURI ] ;
fhir:value [ fhir:v "false"^^xsd:boolean ]     ] ) ;
fhir:key [ fhir:v "EHRSFMR2.1-TI.2.1-04" ] ;
fhir:label [ fhir:v "TI.2.1#04" ] ;
    ( fhir:conformance [ fhir:v "SHALL" ] ) ;
fhir:conditionality [ fhir:v "false"^^xsd:boolean ] ;
fhir:requirement [ fhir:v "The system SHALL capture the current master clock time to establish valid record date and time metadata." ] ;
fhir:derivedFrom [ fhir:v "EHR-S_FM_R1.1 IN.2.2#18" ]
  ] [
    ( fhir:extension [
fhir:url [ fhir:v "http://hl7.org/ehrs/StructureDefinition/requirements-dependent"^^xsd:anyURI ] ;
fhir:value [ fhir:v "false"^^xsd:boolean ]     ] ) ;
fhir:key [ fhir:v "EHRSFMR2.1-TI.2.1-05" ] ;
fhir:label [ fhir:v "TI.2.1#05" ] ;
    ( fhir:conformance [ fhir:v "MAY" ] ) ;
fhir:conditionality [ fhir:v "false"^^xsd:boolean ] ;
fhir:requirement [ fhir:v "The system MAY manage Audit Trigger logging using a common audit engine (e.g., using schema and transports such as specified in the Audit Log specification of IHE Audit Trails and Node Authentication (ATNA) Profile)." ]
  ] ) . #