ISO/HL7 10781 - Electronic Health Record System Functional Model, Release 2.1
0.14.0 - CI Build
ISO/HL7 10781 - Electronic Health Record System Functional Model, Release 2.1 - Local Development build (v0.14.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions
Active as of 2024-06-01 |
Manage Audit Trigger initiated to track system events.
Capture system events, both routine and exceptional, including key metadata (who, what, when, where, why).
TI.2.1.3.1#01 | dependent SHALL |
The system SHALL audit each occurrence when system events are detected according to scope of practice, organizational policy, and/or jurisdictional law. |
TI.2.1.3.1#02 | SHALL |
The system SHALL capture identity of the organization. |
TI.2.1.3.1#03 | conditional SHALL |
IF known, THEN the system SHALL capture identity of the user. |
TI.2.1.3.1#04 | SHALL |
The system SHALL capture identity of the system. |
TI.2.1.3.1#05 | SHALL |
The system SHALL capture the event initiating audit trigger. |
TI.2.1.3.1#06 | SHALL |
The system SHALL capture the date and time of the event initiating audit trigger. |
TI.2.1.3.1#07 | SHALL |
The system SHALL capture identity of the location (i.e., network address). |
TI.2.1.3.1#08 | MAY |
The system MAY capture the rationale for the event initiating audit trigger. |