<Requirements xmlns="http://hl7.org/fhir">
  <id value="EHRSFMR2.1-TI.1.5"/>
  <meta>
    <profile value="http://hl7.org/ehrs/StructureDefinition/FMFunction"/>
  </meta>
  <text>
    <status value="extensions"/>
    <div xmlns="http://www.w3.org/1999/xhtml">
    <span id="description"><b>Statement <a href="https://hl7.org/fhir/versions.html#std-process" title="Normative Content" class="normative-flag">N</a>:</b> <div><p>Limit an EHR-S user's ability to deny (repudiate) data origination, transmission or receipt by that user.</p>
</div></span>

    
    <span id="purpose"><b>Description <a href="https://hl7.org/fhir/versions.html#std-process" title="Informative Content" class="informative-flag">I</a>:</b> <div><p>An EHR-S allows data entry to a patient's electronic health record and it can be a sender or receiver of healthcare information. Non-repudiation is a way to guarantee that the source of the data/record cannot later deny that fact; and that the sender of a message cannot later deny having sent the message; and that the recipient cannot deny having received the message. Components of non-repudiation can include:</p>
<ul>
<li>Digital signature, which serves as a unique identifier for an individual (much like a written signature);</li>
<li>Confirmation service, which utilizes a message transfer agent to create a digital receipt (providing confirmation that a message was sent, and/or received);</li>
<li>Timestamp, which proves that a document existed at a certain date and time;</li>
<li>The use of standardized timekeeping protocols (e.g., the Integrating the Healthcare Enterprise (IHE) Consistent Time Profile).</li>
</ul>
</div></span>
    

    

    
    <span id="requirements"><b>Criteria <a href="https://hl7.org/fhir/versions.html#std-process" title="Normative Content" class="normative-flag">N</a>:</b></span>
    
    <table id="statements" class="grid dict">
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>TI.1.5#01</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                <i>dependent</i>
                
                
                
                <span>SHALL</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>The system SHALL capture the identity of the entity taking the action according to scope of practice, organizational policy, and/or jurisdictional law.</p>
</div></span>
                
                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>TI.1.5#02</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                <i>dependent</i>
                
                
                
                <span>SHALL</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>The system SHALL capture time stamp of the initial entry, modification and exchange of data according to scope of practice, organizational policy, and/or jurisdictional law.</p>
</div></span>
                
                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>TI.1.5#03</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                <i>dependent</i>
                
                
                
                <span>SHALL</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>The system SHALL conform to function [[TI.2]] (Audit) to prevent repudiation of data origination, transmission and receipt according to scope of practice, organizational policy, and/or jurisdictional law.</p>
</div></span>
                
                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>TI.1.5#04</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                <i>dependent</i>
                
                
                
                <span>SHOULD</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>The system SHOULD conform to function [[RI.1.1.4]] (Attest Record Entry Content) to ensure integrity of data and data exchange and thus prevent repudiation of data origination, transmission or receipt according to scope of practice, organizational policy, and/or jurisdictional law.</p>
</div></span>
                
                
            </td>
        </tr>
        
    </table>
</div>
  </text>
  <url value="http://hl7.org/ehrs/Requirements/EHRSFMR2.1-TI.1.5"/>
  <version value="0.14.0"/>
  <name value="TI_1_5_Non_Repudiation"/>
  <title value="TI.1.5 Non-Repudiation (Function)"/>
  <status value="active"/>
  <date value="2024-06-01T08:34:10+00:00"/>
  <publisher value="EHR WG"/>
  <contact>
    <telecom>
      <system value="url"/>
      <value value="http://www.hl7.org/Special/committees/ehr"/>
    </telecom>
  </contact>
  <description
               value="Limit an EHR-S user's ability to deny (repudiate) data origination, transmission or receipt by that user."/>
  <purpose
           value="An EHR-S allows data entry to a patient's electronic health record and it can be a sender or receiver of healthcare information. Non-repudiation is a way to guarantee that the source of the data/record cannot later deny that fact; and that the sender of a message cannot later deny having sent the message; and that the recipient cannot deny having received the message. Components of non-repudiation can include:
- Digital signature, which serves as a unique identifier for an individual (much like a written signature);
- Confirmation service, which utilizes a message transfer agent to create a digital receipt (providing confirmation that a message was sent, and/or received);
- Timestamp, which proves that a document existed at a certain date and time;
- The use of standardized timekeeping protocols (e.g., the Integrating the Healthcare Enterprise (IHE) Consistent Time Profile)."/>
  <statement>
    <extension
               url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
      <valueBoolean value="true"/>
    </extension>
    <key value="EHRSFMR2.1-TI.1.5-01"/>
    <label value="TI.1.5#01"/>
    <conformance value="SHALL"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHALL capture the identity of the entity taking the action according to scope of practice, organizational policy, and/or jurisdictional law."/>
    <derivedFrom value="EHR-S_FM_R1.1 IN.1.5#1"/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
      <valueBoolean value="true"/>
    </extension>
    <key value="EHRSFMR2.1-TI.1.5-02"/>
    <label value="TI.1.5#02"/>
    <conformance value="SHALL"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHALL capture time stamp of the initial entry, modification and exchange of data according to scope of practice, organizational policy, and/or jurisdictional law."/>
    <derivedFrom value="EHR-S_FM_R1.1 IN.1.5#2"/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
      <valueBoolean value="true"/>
    </extension>
    <key value="EHRSFMR2.1-TI.1.5-03"/>
    <label value="TI.1.5#03"/>
    <conformance value="SHALL"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHALL conform to function [[TI.2]] (Audit) to prevent repudiation of data origination, transmission and receipt according to scope of practice, organizational policy, and/or jurisdictional law."/>
    <derivedFrom value="EHR-S_FM_R1.1 IN.1.5#3"/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
      <valueBoolean value="true"/>
    </extension>
    <key value="EHRSFMR2.1-TI.1.5-04"/>
    <label value="TI.1.5#04"/>
    <conformance value="SHOULD"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHOULD conform to function [[RI.1.1.4]] (Attest Record Entry Content) to ensure integrity of data and data exchange and thus prevent repudiation of data origination, transmission or receipt according to scope of practice, organizational policy, and/or jurisdictional law."/>
    <derivedFrom value="EHR-S_FM_R1.1 IN.1.5#4"/>