EHRS-FM IG

ISO/HL7 10781 - Electronic Health Record System Functional Model, Release 2.1
0.14.0 - CI Build

ISO/HL7 10781 - Electronic Health Record System Functional Model, Release 2.1 - Local Development build (v0.14.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions

: RI.1.1.8.1 Evidence of Record Entry Transmit Event (Function) - JSON Representation

Active as of 2024-06-01

Raw json | Download


{
  "resourceType" : "Requirements",
  "id" : "EHRSFMR2.1-RI.1.1.8.1",
  "meta" : {
    "profile" : [
      🔗 "http://hl7.org/ehrs/StructureDefinition/FMFunction"
    ]
  },
  "text" : {
    "status" : "extensions",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">\n    <span id=\"description\"><b>Statement <a href=\"https://hl7.org/fhir/versions.html#std-process\" title=\"Normative Content\" class=\"normative-flag\">N</a>:</b> <div><p>Maintain Evidence of Record Entry Transmit Event</p>\n</div></span>\n\n    \n    <span id=\"purpose\"><b>Description <a href=\"https://hl7.org/fhir/versions.html#std-process\" title=\"Informative Content\" class=\"informative-flag\">I</a>:</b> <div><p>Evidence of Record Entry Transmit Event includes key metadata, ensures health record integrity (and trust) and enables record audit.</p>\n</div></span>\n    \n\n    \n\n    \n    <span id=\"requirements\"><b>Criteria <a href=\"https://hl7.org/fhir/versions.html#std-process\" title=\"Normative Content\" class=\"normative-flag\">N</a>:</b></span>\n    \n    <table id=\"statements\" class=\"grid dict\">\n        \n        <tr>\n            <td style=\"padding-left: 4px;\">\n                \n                <span>RI.1.1.8.1#01</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\">\n                \n                \n                \n                <span>SHALL</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\" class=\"requirement\">\n                \n                <span><div><p>The system SHALL audit each occurrence when Record Entry content is transmitted.</p>\n</div></span>\n                \n                \n            </td>\n        </tr>\n        \n        <tr>\n            <td style=\"padding-left: 4px;\">\n                \n                <span>RI.1.1.8.1#02</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\">\n                \n                \n                \n                <span>SHALL</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\" class=\"requirement\">\n                \n                <span><div><p>The system SHALL capture identity of the organization from which Record Entry content is transmitted.</p>\n</div></span>\n                \n                \n            </td>\n        </tr>\n        \n        <tr>\n            <td style=\"padding-left: 4px;\">\n                \n                <span>RI.1.1.8.1#03</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\">\n                \n                \n                \n                <span>SHALL</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\" class=\"requirement\">\n                \n                <span><div><p>The system SHALL capture identity of the patient who is subject of Record Entry content transmitted.</p>\n</div></span>\n                \n                \n            </td>\n        </tr>\n        \n        <tr>\n            <td style=\"padding-left: 4px;\">\n                \n                <span>RI.1.1.8.1#04</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\">\n                \n                \n                \n                <span>SHALL</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\" class=\"requirement\">\n                \n                <span><div><p>The system SHALL capture identity of the user initiating transmission of Record Entry content.</p>\n</div></span>\n                \n                \n            </td>\n        </tr>\n        \n        <tr>\n            <td style=\"padding-left: 4px;\">\n                \n                <span>RI.1.1.8.1#05</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\">\n                \n                \n                \n                <span>SHALL</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\" class=\"requirement\">\n                \n                <span><div><p>The system SHALL capture identity of the system application which transmitted Record Entry content.</p>\n</div></span>\n                \n                \n            </td>\n        </tr>\n        \n        <tr>\n            <td style=\"padding-left: 4px;\">\n                \n                <span>RI.1.1.8.1#06</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\">\n                \n                \n                \n                <span>SHALL</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\" class=\"requirement\">\n                \n                <span><div><p>The system SHALL capture identity of the system application which received Record Entry content.</p>\n</div></span>\n                \n                \n            </td>\n        </tr>\n        \n        <tr>\n            <td style=\"padding-left: 4px;\">\n                \n                <span>RI.1.1.8.1#07</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\">\n                \n                \n                \n                <span>SHALL</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\" class=\"requirement\">\n                \n                <span><div><p>The system SHALL capture the type of Record Event trigger (i.e., transmit).</p>\n</div></span>\n                \n                \n            </td>\n        </tr>\n        \n        <tr>\n            <td style=\"padding-left: 4px;\">\n                \n                <span>RI.1.1.8.1#08</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\">\n                \n                \n                \n                <span>SHALL</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\" class=\"requirement\">\n                \n                <span><div><p>The system SHALL capture the date and time Record Entry content is transmitted.</p>\n</div></span>\n                \n                \n            </td>\n        </tr>\n        \n        <tr>\n            <td style=\"padding-left: 4px;\">\n                \n                <span>RI.1.1.8.1#09</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\">\n                \n                \n                \n                <span>SHOULD</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\" class=\"requirement\">\n                \n                <span><div><p>The system SHOULD capture identity of the location (i.e., network address) from which the Record Entry is transmitted/disclosed.</p>\n</div></span>\n                \n                \n            </td>\n        </tr>\n        \n        <tr>\n            <td style=\"padding-left: 4px;\">\n                \n                <span>RI.1.1.8.1#10</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\">\n                \n                \n                \n                <span>SHALL</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\" class=\"requirement\">\n                \n                <span><div><p>The system SHALL capture the location (network address) to which the Record Entry is transmitted/disclosed.</p>\n</div></span>\n                \n                \n            </td>\n        </tr>\n        \n        <tr>\n            <td style=\"padding-left: 4px;\">\n                \n                <span>RI.1.1.8.1#11</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\">\n                \n                \n                \n                <span>MAY</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\" class=\"requirement\">\n                \n                <span><div><p>The system MAY capture the rationale for transmitting Record Entry content.</p>\n</div></span>\n                \n                \n            </td>\n        </tr>\n        \n        <tr>\n            <td style=\"padding-left: 4px;\">\n                \n                <span>RI.1.1.8.1#12</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\">\n                \n                \n                \n                <span>SHALL</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\" class=\"requirement\">\n                \n                <span><div><p>The system SHALL capture the type of Record Entry content transmitted/disclosed (e.g., original, amended, updated data).</p>\n</div></span>\n                \n                \n            </td>\n        </tr>\n        \n        <tr>\n            <td style=\"padding-left: 4px;\">\n                \n                <span>RI.1.1.8.1#13</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\">\n                \n                \n                \n                <span>MAY</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\" class=\"requirement\">\n                \n                <span><div><p>The system MAY capture the data, document or other identifier for transmitted/disclosed Record Entry.</p>\n</div></span>\n                \n                \n            </td>\n        </tr>\n        \n        <tr>\n            <td style=\"padding-left: 4px;\">\n                \n                <span>RI.1.1.8.1#14</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\">\n                \n                \n                \n                <span>MAY</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\" class=\"requirement\">\n                \n                <span><div><p>The system MAY capture data elements for transmitted/disclosed Record Entry.</p>\n</div></span>\n                \n                \n            </td>\n        </tr>\n        \n        <tr>\n            <td style=\"padding-left: 4px;\">\n                \n                <span>RI.1.1.8.1#15</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\">\n                \n                <i>dependent</i>\n                \n                \n                \n                <span>SHALL</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\" class=\"requirement\">\n                \n                <span><div><p>The system SHALL capture when a Record Entry transmit occurrence is known to be a disclosure, according to scope of practice, organizational policy, and/or jurisdictional law.</p>\n</div></span>\n                \n                \n            </td>\n        </tr>\n        \n        <tr>\n            <td style=\"padding-left: 4px;\">\n                \n                <span>RI.1.1.8.1#16</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\">\n                \n                \n                \n                <span>SHOULD</span>\n                \n            </td>\n            <td style=\"padding-left: 4px;\" class=\"requirement\">\n                \n                <span><div><p>The system SHOULD capture known and applicable permissions regarding Record Entry content transmitted including confidentiality codes, patient consent authorizations, privacy policy pointers.</p>\n</div></span>\n                \n                \n            </td>\n        </tr>\n        \n    </table>\n</div>"
  },
  "url" : "http://hl7.org/ehrs/Requirements/EHRSFMR2.1-RI.1.1.8.1",
  "version" : "0.14.0",
  "name" : "RI_1_1_8_1_Evidence_of_Record_Entry_Transmit_Event",
  "title" : "RI.1.1.8.1 Evidence of Record Entry Transmit Event (Function)",
  "status" : "active",
  "date" : "2024-06-01T08:34:10+00:00",
  "publisher" : "EHR WG",
  "contact" : [
    {
      "telecom" : [
        {
          "system" : "url",
          "value" : "http://www.hl7.org/Special/committees/ehr"
        }
      ]
    }
  ],
  "description" : "Maintain Evidence of Record Entry Transmit Event",
  "purpose" : "Evidence of Record Entry Transmit Event includes key metadata, ensures health record integrity (and trust) and enables record audit.",
  "statement" : [
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.8.1-01",
      "label" : "RI.1.1.8.1#01",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : false,
      "requirement" : "The system SHALL audit each occurrence when Record Entry content is transmitted.",
      "derivedFrom" : "EHR-LM_R1 14.5.1"
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.8.1-02",
      "label" : "RI.1.1.8.1#02",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : false,
      "requirement" : "The system SHALL capture identity of the organization from which Record Entry content is transmitted."
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.8.1-03",
      "label" : "RI.1.1.8.1#03",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : false,
      "requirement" : "The system SHALL capture identity of the patient who is subject of Record Entry content transmitted."
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.8.1-04",
      "label" : "RI.1.1.8.1#04",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : false,
      "requirement" : "The system SHALL capture identity of the user initiating transmission of Record Entry content."
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.8.1-05",
      "label" : "RI.1.1.8.1#05",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : false,
      "requirement" : "The system SHALL capture identity of the system application which transmitted Record Entry content."
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.8.1-06",
      "label" : "RI.1.1.8.1#06",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : false,
      "requirement" : "The system SHALL capture identity of the system application which received Record Entry content."
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.8.1-07",
      "label" : "RI.1.1.8.1#07",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : false,
      "requirement" : "The system SHALL capture the type of Record Event trigger (i.e., transmit)."
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.8.1-08",
      "label" : "RI.1.1.8.1#08",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : false,
      "requirement" : "The system SHALL capture the date and time Record Entry content is transmitted."
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.8.1-09",
      "label" : "RI.1.1.8.1#09",
      "conformance" : [
        "SHOULD"
      ],
      "conditionality" : false,
      "requirement" : "The system SHOULD capture identity of the location (i.e., network address) from which the Record Entry is transmitted/disclosed."
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.8.1-10",
      "label" : "RI.1.1.8.1#10",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : false,
      "requirement" : "The system SHALL capture the location (network address) to which the Record Entry is transmitted/disclosed."
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.8.1-11",
      "label" : "RI.1.1.8.1#11",
      "conformance" : [
        "MAY"
      ],
      "conditionality" : false,
      "requirement" : "The system MAY capture the rationale for transmitting Record Entry content."
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.8.1-12",
      "label" : "RI.1.1.8.1#12",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : false,
      "requirement" : "The system SHALL capture the type of Record Entry content transmitted/disclosed (e.g., original, amended, updated data)."
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.8.1-13",
      "label" : "RI.1.1.8.1#13",
      "conformance" : [
        "MAY"
      ],
      "conditionality" : false,
      "requirement" : "The system MAY capture the data, document or other identifier for transmitted/disclosed Record Entry."
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.8.1-14",
      "label" : "RI.1.1.8.1#14",
      "conformance" : [
        "MAY"
      ],
      "conditionality" : false,
      "requirement" : "The system MAY capture data elements for transmitted/disclosed Record Entry."
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : true
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.8.1-15",
      "label" : "RI.1.1.8.1#15",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : false,
      "requirement" : "The system SHALL capture when a Record Entry transmit occurrence is known to be a disclosure, according to scope of practice, organizational policy, and/or jurisdictional law."
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-RI.1.1.8.1-16",
      "label" : "RI.1.1.8.1#16",
      "conformance" : [
        "SHOULD"
      ],
      "conditionality" : false,
      "requirement" : "The system SHOULD capture known and applicable permissions regarding Record Entry content transmitted including confidentiality codes, patient consent authorizations, privacy policy pointers."
    }
  ]
}