ISO/HL7 10781 - Electronic Health Record System Functional Model, Release 2.1 - Local Development build (v0.14.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions
Active as of 2024-06-01 |
@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .
# - resource -------------------------------------------------------------------
a fhir:Requirements ;
fhir:nodeRole fhir:treeRoot ;
fhir:id [ fhir:v "EHRSFMR2.1-RI.1.1.7"] ; #
fhir:meta [
( fhir:profile [
fhir:v "http://hl7.org/ehrs/StructureDefinition/FMFunction"^^xsd:anyURI ;
fhir:link <http://hl7.org/ehrs/StructureDefinition/FMFunction> ] )
] ; #
fhir:text [
fhir:status [ fhir:v "extensions" ] ;
fhir:div "<div xmlns=\"http://www.w3.org/1999/xhtml\">\n <span id=\"description\"><b>Statement <a href=\"https://hl7.org/fhir/versions.html#std-process\" title=\"Normative Content\" class=\"normative-flag\">N</a>:</b> <div><p>Disclose Record Entry Content (1 or more instances)</p>\n</div></span>\n\n \n <span id=\"purpose\"><b>Description <a href=\"https://hl7.org/fhir/versions.html#std-process\" title=\"Informative Content\" class=\"informative-flag\">I</a>:</b> <div><p>Occurs when an agent causes the system to release, transfer, provision access to, or otherwise divulge record entry content.</p>\n<p>Reference: ISO 21089-2018, Section 15.7.</p>\n</div></span>\n \n\n \n\n \n <span id=\"requirements\"><b>Criteria <a href=\"https://hl7.org/fhir/versions.html#std-process\" title=\"Normative Content\" class=\"normative-flag\">N</a>:</b></span>\n \n <table id=\"statements\" class=\"grid dict\">\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.7#01</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL provide the ability to capture the identity of the patient or individual subject to whom Record Entry content was transmitted/disclosed.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.7#02</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n <i>dependent</i>\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL capture a log entry for disclosure of protected Record Entry content, according to scope of practice, organizational policy, and/or jurisdictional law.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.7#03</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n <i>dependent</i>\n \n \n <i>conditional</i>\n \n \n <span>SHOULD</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>IF the identity of a specific recipient has been stored, THEN the system SHOULD render protected Record Entry content based on established permissions and according to scope of practice, organizational policy, and/or jurisdictional law.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.7#04</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n <i>conditional</i>\n \n \n <span>SHOULD</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>IF known and explicit as to Record Entry content being transmitted, THEN the system SHOULD transmit corresponding authorizations and patient consent permissions.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.7#05</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL conform to function [[TI.1.6]] (Secure Data Exchange).</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.7#06</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL provide the ability to extract Record Entry content prior to disclosure, conforming to function [[RI.1.1.13]] (Extract Record Entry Content).</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.7#07</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL provide the ability to de-identify Record Entry content prior to disclosure, conforming to function [[RI.1.1.10]] (De-Identify Record Entries).</p>\n</div></span>\n \n \n </td>\n </tr>\n \n </table>\n</div>"
] ; #
fhir:url [ fhir:v "http://hl7.org/ehrs/Requirements/EHRSFMR2.1-RI.1.1.7"^^xsd:anyURI] ; #
fhir:version [ fhir:v "0.14.0"] ; #
fhir:name [ fhir:v "RI_1_1_7_Disclose_Record_Lifecycle_Event"] ; #
fhir:title [ fhir:v "RI.1.1.7 Disclose Record Lifecycle Event (Function)"] ; #
fhir:status [ fhir:v "active"] ; #
fhir:date [ fhir:v "2024-06-01T08:34:10+00:00"^^xsd:dateTime] ; #
fhir:publisher [ fhir:v "EHR WG"] ; #
fhir:contact ( [
( fhir:telecom [
fhir:system [ fhir:v "url" ] ;
fhir:value [ fhir:v "http://www.hl7.org/Special/committees/ehr" ] ] )
] ) ; #
fhir:description [ fhir:v "Disclose Record Entry Content (1 or more instances)"] ; #
fhir:purpose [ fhir:v "Occurs when an agent causes the system to release, transfer, provision access to, or otherwise divulge record entry content. \n\nReference: ISO 21089-2018, Section 15.7."] ; #
fhir:statement ( [
( fhir:extension [
fhir:url [ fhir:v "http://hl7.org/ehrs/StructureDefinition/requirements-dependent"^^xsd:anyURI ] ;
fhir:value [ fhir:v "false"^^xsd:boolean ] ] ) ;
fhir:key [ fhir:v "EHRSFMR2.1-RI.1.1.7-01" ] ;
fhir:label [ fhir:v "RI.1.1.7#01" ] ;
( fhir:conformance [ fhir:v "SHALL" ] ) ;
fhir:conditionality [ fhir:v "false"^^xsd:boolean ] ;
fhir:requirement [ fhir:v "The system SHALL provide the ability to capture the identity of the patient or individual subject to whom Record Entry content was transmitted/disclosed." ]
] [
( fhir:extension [
fhir:url [ fhir:v "http://hl7.org/ehrs/StructureDefinition/requirements-dependent"^^xsd:anyURI ] ;
fhir:value [ fhir:v "true"^^xsd:boolean ] ] ) ;
fhir:key [ fhir:v "EHRSFMR2.1-RI.1.1.7-02" ] ;
fhir:label [ fhir:v "RI.1.1.7#02" ] ;
( fhir:conformance [ fhir:v "SHALL" ] ) ;
fhir:conditionality [ fhir:v "false"^^xsd:boolean ] ;
fhir:requirement [ fhir:v "The system SHALL capture a log entry for disclosure of protected Record Entry content, according to scope of practice, organizational policy, and/or jurisdictional law." ]
] [
( fhir:extension [
fhir:url [ fhir:v "http://hl7.org/ehrs/StructureDefinition/requirements-dependent"^^xsd:anyURI ] ;
fhir:value [ fhir:v "true"^^xsd:boolean ] ] ) ;
fhir:key [ fhir:v "EHRSFMR2.1-RI.1.1.7-03" ] ;
fhir:label [ fhir:v "RI.1.1.7#03" ] ;
( fhir:conformance [ fhir:v "SHOULD" ] ) ;
fhir:conditionality [ fhir:v "true"^^xsd:boolean ] ;
fhir:requirement [ fhir:v "IF the identity of a specific recipient has been stored, THEN the system SHOULD render protected Record Entry content based on established permissions and according to scope of practice, organizational policy, and/or jurisdictional law." ]
] [
( fhir:extension [
fhir:url [ fhir:v "http://hl7.org/ehrs/StructureDefinition/requirements-dependent"^^xsd:anyURI ] ;
fhir:value [ fhir:v "false"^^xsd:boolean ] ] ) ;
fhir:key [ fhir:v "EHRSFMR2.1-RI.1.1.7-04" ] ;
fhir:label [ fhir:v "RI.1.1.7#04" ] ;
( fhir:conformance [ fhir:v "SHOULD" ] ) ;
fhir:conditionality [ fhir:v "true"^^xsd:boolean ] ;
fhir:requirement [ fhir:v "IF known and explicit as to Record Entry content being transmitted, THEN the system SHOULD transmit corresponding authorizations and patient consent permissions." ]
] [
( fhir:extension [
fhir:url [ fhir:v "http://hl7.org/ehrs/StructureDefinition/requirements-dependent"^^xsd:anyURI ] ;
fhir:value [ fhir:v "false"^^xsd:boolean ] ] ) ;
fhir:key [ fhir:v "EHRSFMR2.1-RI.1.1.7-05" ] ;
fhir:label [ fhir:v "RI.1.1.7#05" ] ;
( fhir:conformance [ fhir:v "SHALL" ] ) ;
fhir:conditionality [ fhir:v "false"^^xsd:boolean ] ;
fhir:requirement [ fhir:v "The system SHALL conform to function [[TI.1.6]] (Secure Data Exchange)." ]
] [
( fhir:extension [
fhir:url [ fhir:v "http://hl7.org/ehrs/StructureDefinition/requirements-dependent"^^xsd:anyURI ] ;
fhir:value [ fhir:v "false"^^xsd:boolean ] ] ) ;
fhir:key [ fhir:v "EHRSFMR2.1-RI.1.1.7-06" ] ;
fhir:label [ fhir:v "RI.1.1.7#06" ] ;
( fhir:conformance [ fhir:v "SHALL" ] ) ;
fhir:conditionality [ fhir:v "false"^^xsd:boolean ] ;
fhir:requirement [ fhir:v "The system SHALL provide the ability to extract Record Entry content prior to disclosure, conforming to function [[RI.1.1.13]] (Extract Record Entry Content)." ]
] [
( fhir:extension [
fhir:url [ fhir:v "http://hl7.org/ehrs/StructureDefinition/requirements-dependent"^^xsd:anyURI ] ;
fhir:value [ fhir:v "false"^^xsd:boolean ] ] ) ;
fhir:key [ fhir:v "EHRSFMR2.1-RI.1.1.7-07" ] ;
fhir:label [ fhir:v "RI.1.1.7#07" ] ;
( fhir:conformance [ fhir:v "SHALL" ] ) ;
fhir:conditionality [ fhir:v "false"^^xsd:boolean ] ;
fhir:requirement [ fhir:v "The system SHALL provide the ability to de-identify Record Entry content prior to disclosure, conforming to function [[RI.1.1.10]] (De-Identify Record Entries)." ]
] ) . #
IG © 2023 EHR WG. Package hl7.ehrsfmr21.base#0.14.0 based on FHIR 5.0.0. Generated 2024-06-01