EHRS-FM IG

ISO/HL7 10781 - Electronic Health Record System Functional Model, Release 2.1
0.14.0 - CI Build

ISO/HL7 10781 - Electronic Health Record System Functional Model, Release 2.1 - Local Development build (v0.14.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions

: RI.1.1.7.1 Evidence of Record Entry Disclosure Event (Function) - XML Representation

Active as of 2024-06-01

Raw xml | Download



<Requirements xmlns="http://hl7.org/fhir">
  <id value="EHRSFMR2.1-RI.1.1.7.1"/>
  <meta>
    <profile value="http://hl7.org/ehrs/StructureDefinition/FMFunction"/>
  </meta>
  <text>
    <status value="extensions"/>
    <div xmlns="http://www.w3.org/1999/xhtml">
    <span id="description"><b>Statement <a href="https://hl7.org/fhir/versions.html#std-process" title="Normative Content" class="normative-flag">N</a>:</b> <div><p>Maintain Evidence of Record Entry Disclosure Event</p>
</div></span>

    
    <span id="purpose"><b>Description <a href="https://hl7.org/fhir/versions.html#std-process" title="Informative Content" class="informative-flag">I</a>:</b> <div><p>Evidence of Record Entry Disclosure Event includes key metadata, ensures health record integrity (and trust) and enables record audit.</p>
</div></span>
    

    

    
    <span id="requirements"><b>Criteria <a href="https://hl7.org/fhir/versions.html#std-process" title="Normative Content" class="normative-flag">N</a>:</b></span>
    
    <table id="statements" class="grid dict">
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>RI.1.1.7.1#01</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                <i>dependent</i>
                
                
                
                <span>SHALL</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>The system SHALL audit each occurrence when Record Entry content is disclosed according to scope of practice, organizational policy, and/or jurisdictional law.</p>
</div></span>
                
                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>RI.1.1.7.1#02</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                
                
                <span>SHALL</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>The system SHALL capture identity of the organization from which Record Entry content is disclosed.</p>
</div></span>
                
                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>RI.1.1.7.1#03</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                
                
                <span>SHALL</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>The system SHALL capture identity of the patient who is subject of Record Entry content disclosed.</p>
</div></span>
                
                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>RI.1.1.7.1#04</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                
                
                <span>SHALL</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>The system SHALL capture identity of the user initiating disclosure of Record Entry content.</p>
</div></span>
                
                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>RI.1.1.7.1#05</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                
                
                <span>SHALL</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>The system SHALL capture identity of the system application from which Record Entry content is disclosed.</p>
</div></span>
                
                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>RI.1.1.7.1#06</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                
                
                <span>SHALL</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>The system SHALL capture the type of Record Event trigger (i.e., disclose).</p>
</div></span>
                
                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>RI.1.1.7.1#07</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                
                
                <span>SHALL</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>The system SHALL capture the date and time Record Entry content is disclosed.</p>
</div></span>
                
                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>RI.1.1.7.1#08</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                
                
                <span>SHOULD</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>The system SHOULD capture identity of the location (i.e., network address) where Record Entry content is disclosed.</p>
</div></span>
                
                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>RI.1.1.7.1#09</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                
                
                <span>SHOULD</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>The system SHOULD capture the rationale for disclosing Record Entry content.</p>
</div></span>
                
                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>RI.1.1.7.1#10</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                
                
                <span>MAY</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>The system MAY capture the data, document or other identifier for Record Entry content disclosed.</p>
</div></span>
                
                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>RI.1.1.7.1#11</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                <i>dependent</i>
                
                
                
                <span>SHALL</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>The system SHALL capture that this is an occurrence when Record Entry content is known to be disclosed, according to scope of practice, organizational policy, and/or jurisdictional law.</p>
</div></span>
                
                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>RI.1.1.7.1#12</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                
                
                <span>SHOULD</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>The system SHOULD capture known and applicable permissions regarding Record Entry content disclosed including confidentiality codes, patient consent authorizations, privacy policy pointers.</p>
</div></span>
                
                
            </td>
        </tr>
        
    </table>
</div>
  </text>
  <url value="http://hl7.org/ehrs/Requirements/EHRSFMR2.1-RI.1.1.7.1"/>
  <version value="0.14.0"/>
  <name value="RI_1_1_7_1_Evidence_of_Record_Entry_Disclosure_Event"/>
  <title
         value="RI.1.1.7.1 Evidence of Record Entry Disclosure Event (Function)"/>
  <status value="active"/>
  <date value="2024-06-01T08:34:10+00:00"/>
  <publisher value="EHR WG"/>
  <contact>
    <telecom>
      <system value="url"/>
      <value value="http://www.hl7.org/Special/committees/ehr"/>
    </telecom>
  </contact>
  <description value="Maintain Evidence of Record Entry Disclosure Event"/>
  <purpose
           value="Evidence of Record Entry Disclosure Event includes key metadata, ensures health record integrity (and trust) and enables record audit."/>
  <statement>
    <extension
               url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
      <valueBoolean value="true"/>
    </extension>
    <key value="EHRSFMR2.1-RI.1.1.7.1-01"/>
    <label value="RI.1.1.7.1#01"/>
    <conformance value="SHALL"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHALL audit each occurrence when Record Entry content is disclosed according to scope of practice, organizational policy, and/or jurisdictional law."/>
    <derivedFrom value="EHR-LM_R1 14.5.1"/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="EHRSFMR2.1-RI.1.1.7.1-02"/>
    <label value="RI.1.1.7.1#02"/>
    <conformance value="SHALL"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHALL capture identity of the organization from which Record Entry content is disclosed."/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="EHRSFMR2.1-RI.1.1.7.1-03"/>
    <label value="RI.1.1.7.1#03"/>
    <conformance value="SHALL"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHALL capture identity of the patient who is subject of Record Entry content disclosed."/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="EHRSFMR2.1-RI.1.1.7.1-04"/>
    <label value="RI.1.1.7.1#04"/>
    <conformance value="SHALL"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHALL capture identity of the user initiating disclosure of Record Entry content."/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="EHRSFMR2.1-RI.1.1.7.1-05"/>
    <label value="RI.1.1.7.1#05"/>
    <conformance value="SHALL"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHALL capture identity of the system application from which Record Entry content is disclosed."/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="EHRSFMR2.1-RI.1.1.7.1-06"/>
    <label value="RI.1.1.7.1#06"/>
    <conformance value="SHALL"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHALL capture the type of Record Event trigger (i.e., disclose)."/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="EHRSFMR2.1-RI.1.1.7.1-07"/>
    <label value="RI.1.1.7.1#07"/>
    <conformance value="SHALL"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHALL capture the date and time Record Entry content is disclosed."/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="EHRSFMR2.1-RI.1.1.7.1-08"/>
    <label value="RI.1.1.7.1#08"/>
    <conformance value="SHOULD"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHOULD capture identity of the location (i.e., network address) where Record Entry content is disclosed."/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="EHRSFMR2.1-RI.1.1.7.1-09"/>
    <label value="RI.1.1.7.1#09"/>
    <conformance value="SHOULD"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHOULD capture the rationale for disclosing Record Entry content."/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="EHRSFMR2.1-RI.1.1.7.1-10"/>
    <label value="RI.1.1.7.1#10"/>
    <conformance value="MAY"/>
    <conditionality value="false"/>
    <requirement
                 value="The system MAY capture the data, document or other identifier for Record Entry content disclosed."/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
      <valueBoolean value="true"/>
    </extension>
    <key value="EHRSFMR2.1-RI.1.1.7.1-11"/>
    <label value="RI.1.1.7.1#11"/>
    <conformance value="SHALL"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHALL capture that this is an occurrence when Record Entry content is known to be disclosed, according to scope of practice, organizational policy, and/or jurisdictional law."/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="EHRSFMR2.1-RI.1.1.7.1-12"/>
    <label value="RI.1.1.7.1#12"/>
    <conformance value="SHOULD"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHOULD capture known and applicable permissions regarding Record Entry content disclosed including confidentiality codes, patient consent authorizations, privacy policy pointers."/>
  </statement>