ISO/HL7 10781 - Electronic Health Record System Functional Model, Release 2.1
0.14.0 - CI Build
ISO/HL7 10781 - Electronic Health Record System Functional Model, Release 2.1 - Local Development build (v0.14.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions
Active as of 2024-06-01 |
<Requirements xmlns="http://hl7.org/fhir">
<id value="EHRSFMR2.1-RI.1.1.7.1"/>
<meta>
<profile value="http://hl7.org/ehrs/StructureDefinition/FMFunction"/>
</meta>
<text>
<status value="extensions"/>
<div xmlns="http://www.w3.org/1999/xhtml">
<span id="description"><b>Statement <a href="https://hl7.org/fhir/versions.html#std-process" title="Normative Content" class="normative-flag">N</a>:</b> <div><p>Maintain Evidence of Record Entry Disclosure Event</p>
</div></span>
<span id="purpose"><b>Description <a href="https://hl7.org/fhir/versions.html#std-process" title="Informative Content" class="informative-flag">I</a>:</b> <div><p>Evidence of Record Entry Disclosure Event includes key metadata, ensures health record integrity (and trust) and enables record audit.</p>
</div></span>
<span id="requirements"><b>Criteria <a href="https://hl7.org/fhir/versions.html#std-process" title="Normative Content" class="normative-flag">N</a>:</b></span>
<table id="statements" class="grid dict">
<tr>
<td style="padding-left: 4px;">
<span>RI.1.1.7.1#01</span>
</td>
<td style="padding-left: 4px;">
<i>dependent</i>
<span>SHALL</span>
</td>
<td style="padding-left: 4px;" class="requirement">
<span><div><p>The system SHALL audit each occurrence when Record Entry content is disclosed according to scope of practice, organizational policy, and/or jurisdictional law.</p>
</div></span>
</td>
</tr>
<tr>
<td style="padding-left: 4px;">
<span>RI.1.1.7.1#02</span>
</td>
<td style="padding-left: 4px;">
<span>SHALL</span>
</td>
<td style="padding-left: 4px;" class="requirement">
<span><div><p>The system SHALL capture identity of the organization from which Record Entry content is disclosed.</p>
</div></span>
</td>
</tr>
<tr>
<td style="padding-left: 4px;">
<span>RI.1.1.7.1#03</span>
</td>
<td style="padding-left: 4px;">
<span>SHALL</span>
</td>
<td style="padding-left: 4px;" class="requirement">
<span><div><p>The system SHALL capture identity of the patient who is subject of Record Entry content disclosed.</p>
</div></span>
</td>
</tr>
<tr>
<td style="padding-left: 4px;">
<span>RI.1.1.7.1#04</span>
</td>
<td style="padding-left: 4px;">
<span>SHALL</span>
</td>
<td style="padding-left: 4px;" class="requirement">
<span><div><p>The system SHALL capture identity of the user initiating disclosure of Record Entry content.</p>
</div></span>
</td>
</tr>
<tr>
<td style="padding-left: 4px;">
<span>RI.1.1.7.1#05</span>
</td>
<td style="padding-left: 4px;">
<span>SHALL</span>
</td>
<td style="padding-left: 4px;" class="requirement">
<span><div><p>The system SHALL capture identity of the system application from which Record Entry content is disclosed.</p>
</div></span>
</td>
</tr>
<tr>
<td style="padding-left: 4px;">
<span>RI.1.1.7.1#06</span>
</td>
<td style="padding-left: 4px;">
<span>SHALL</span>
</td>
<td style="padding-left: 4px;" class="requirement">
<span><div><p>The system SHALL capture the type of Record Event trigger (i.e., disclose).</p>
</div></span>
</td>
</tr>
<tr>
<td style="padding-left: 4px;">
<span>RI.1.1.7.1#07</span>
</td>
<td style="padding-left: 4px;">
<span>SHALL</span>
</td>
<td style="padding-left: 4px;" class="requirement">
<span><div><p>The system SHALL capture the date and time Record Entry content is disclosed.</p>
</div></span>
</td>
</tr>
<tr>
<td style="padding-left: 4px;">
<span>RI.1.1.7.1#08</span>
</td>
<td style="padding-left: 4px;">
<span>SHOULD</span>
</td>
<td style="padding-left: 4px;" class="requirement">
<span><div><p>The system SHOULD capture identity of the location (i.e., network address) where Record Entry content is disclosed.</p>
</div></span>
</td>
</tr>
<tr>
<td style="padding-left: 4px;">
<span>RI.1.1.7.1#09</span>
</td>
<td style="padding-left: 4px;">
<span>SHOULD</span>
</td>
<td style="padding-left: 4px;" class="requirement">
<span><div><p>The system SHOULD capture the rationale for disclosing Record Entry content.</p>
</div></span>
</td>
</tr>
<tr>
<td style="padding-left: 4px;">
<span>RI.1.1.7.1#10</span>
</td>
<td style="padding-left: 4px;">
<span>MAY</span>
</td>
<td style="padding-left: 4px;" class="requirement">
<span><div><p>The system MAY capture the data, document or other identifier for Record Entry content disclosed.</p>
</div></span>
</td>
</tr>
<tr>
<td style="padding-left: 4px;">
<span>RI.1.1.7.1#11</span>
</td>
<td style="padding-left: 4px;">
<i>dependent</i>
<span>SHALL</span>
</td>
<td style="padding-left: 4px;" class="requirement">
<span><div><p>The system SHALL capture that this is an occurrence when Record Entry content is known to be disclosed, according to scope of practice, organizational policy, and/or jurisdictional law.</p>
</div></span>
</td>
</tr>
<tr>
<td style="padding-left: 4px;">
<span>RI.1.1.7.1#12</span>
</td>
<td style="padding-left: 4px;">
<span>SHOULD</span>
</td>
<td style="padding-left: 4px;" class="requirement">
<span><div><p>The system SHOULD capture known and applicable permissions regarding Record Entry content disclosed including confidentiality codes, patient consent authorizations, privacy policy pointers.</p>
</div></span>
</td>
</tr>
</table>
</div>
</text>
<url value="http://hl7.org/ehrs/Requirements/EHRSFMR2.1-RI.1.1.7.1"/>
<version value="0.14.0"/>
<name value="RI_1_1_7_1_Evidence_of_Record_Entry_Disclosure_Event"/>
<title
value="RI.1.1.7.1 Evidence of Record Entry Disclosure Event (Function)"/>
<status value="active"/>
<date value="2024-06-01T08:34:10+00:00"/>
<publisher value="EHR WG"/>
<contact>
<telecom>
<system value="url"/>
<value value="http://www.hl7.org/Special/committees/ehr"/>
</telecom>
</contact>
<description value="Maintain Evidence of Record Entry Disclosure Event"/>
<purpose
value="Evidence of Record Entry Disclosure Event includes key metadata, ensures health record integrity (and trust) and enables record audit."/>
<statement>
<extension
url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
<valueBoolean value="true"/>
</extension>
<key value="EHRSFMR2.1-RI.1.1.7.1-01"/>
<label value="RI.1.1.7.1#01"/>
<conformance value="SHALL"/>
<conditionality value="false"/>
<requirement
value="The system SHALL audit each occurrence when Record Entry content is disclosed according to scope of practice, organizational policy, and/or jurisdictional law."/>
<derivedFrom value="EHR-LM_R1 14.5.1"/>
</statement>
<statement>
<extension
url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
<valueBoolean value="false"/>
</extension>
<key value="EHRSFMR2.1-RI.1.1.7.1-02"/>
<label value="RI.1.1.7.1#02"/>
<conformance value="SHALL"/>
<conditionality value="false"/>
<requirement
value="The system SHALL capture identity of the organization from which Record Entry content is disclosed."/>
</statement>
<statement>
<extension
url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
<valueBoolean value="false"/>
</extension>
<key value="EHRSFMR2.1-RI.1.1.7.1-03"/>
<label value="RI.1.1.7.1#03"/>
<conformance value="SHALL"/>
<conditionality value="false"/>
<requirement
value="The system SHALL capture identity of the patient who is subject of Record Entry content disclosed."/>
</statement>
<statement>
<extension
url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
<valueBoolean value="false"/>
</extension>
<key value="EHRSFMR2.1-RI.1.1.7.1-04"/>
<label value="RI.1.1.7.1#04"/>
<conformance value="SHALL"/>
<conditionality value="false"/>
<requirement
value="The system SHALL capture identity of the user initiating disclosure of Record Entry content."/>
</statement>
<statement>
<extension
url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
<valueBoolean value="false"/>
</extension>
<key value="EHRSFMR2.1-RI.1.1.7.1-05"/>
<label value="RI.1.1.7.1#05"/>
<conformance value="SHALL"/>
<conditionality value="false"/>
<requirement
value="The system SHALL capture identity of the system application from which Record Entry content is disclosed."/>
</statement>
<statement>
<extension
url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
<valueBoolean value="false"/>
</extension>
<key value="EHRSFMR2.1-RI.1.1.7.1-06"/>
<label value="RI.1.1.7.1#06"/>
<conformance value="SHALL"/>
<conditionality value="false"/>
<requirement
value="The system SHALL capture the type of Record Event trigger (i.e., disclose)."/>
</statement>
<statement>
<extension
url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
<valueBoolean value="false"/>
</extension>
<key value="EHRSFMR2.1-RI.1.1.7.1-07"/>
<label value="RI.1.1.7.1#07"/>
<conformance value="SHALL"/>
<conditionality value="false"/>
<requirement
value="The system SHALL capture the date and time Record Entry content is disclosed."/>
</statement>
<statement>
<extension
url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
<valueBoolean value="false"/>
</extension>
<key value="EHRSFMR2.1-RI.1.1.7.1-08"/>
<label value="RI.1.1.7.1#08"/>
<conformance value="SHOULD"/>
<conditionality value="false"/>
<requirement
value="The system SHOULD capture identity of the location (i.e., network address) where Record Entry content is disclosed."/>
</statement>
<statement>
<extension
url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
<valueBoolean value="false"/>
</extension>
<key value="EHRSFMR2.1-RI.1.1.7.1-09"/>
<label value="RI.1.1.7.1#09"/>
<conformance value="SHOULD"/>
<conditionality value="false"/>
<requirement
value="The system SHOULD capture the rationale for disclosing Record Entry content."/>
</statement>
<statement>
<extension
url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
<valueBoolean value="false"/>
</extension>
<key value="EHRSFMR2.1-RI.1.1.7.1-10"/>
<label value="RI.1.1.7.1#10"/>
<conformance value="MAY"/>
<conditionality value="false"/>
<requirement
value="The system MAY capture the data, document or other identifier for Record Entry content disclosed."/>
</statement>
<statement>
<extension
url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
<valueBoolean value="true"/>
</extension>
<key value="EHRSFMR2.1-RI.1.1.7.1-11"/>
<label value="RI.1.1.7.1#11"/>
<conformance value="SHALL"/>
<conditionality value="false"/>
<requirement
value="The system SHALL capture that this is an occurrence when Record Entry content is known to be disclosed, according to scope of practice, organizational policy, and/or jurisdictional law."/>
</statement>
<statement>
<extension
url="http://hl7.org/ehrs/StructureDefinition/requirements-dependent">
<valueBoolean value="false"/>
</extension>
<key value="EHRSFMR2.1-RI.1.1.7.1-12"/>
<label value="RI.1.1.7.1#12"/>
<conformance value="SHOULD"/>
<conditionality value="false"/>
<requirement
value="The system SHOULD capture known and applicable permissions regarding Record Entry content disclosed including confidentiality codes, patient consent authorizations, privacy policy pointers."/>
</statement>
</Requirements>