ISO/HL7 10781 - Electronic Health Record System Functional Model, Release 2.1
0.14.0 - CI Build
ISO/HL7 10781 - Electronic Health Record System Functional Model, Release 2.1 - Local Development build (v0.14.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions
Active as of 2024-06-01 |
{
"resourceType" : "Requirements",
"id" : "EHRSFMR2.1-RI.1.1.26",
"meta" : {
"profile" : [
🔗 "http://hl7.org/ehrs/StructureDefinition/FMFunction"
]
},
"text" : {
"status" : "extensions",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">\n <span id=\"description\"><b>Statement <a href=\"https://hl7.org/fhir/versions.html#std-process\" title=\"Normative Content\" class=\"normative-flag\">N</a>:</b> <div><p>Encrypt Record Entries (1 or more instances)</p>\n</div></span>\n\n \n <span id=\"purpose\"><b>Description <a href=\"https://hl7.org/fhir/versions.html#std-process\" title=\"Informative Content\" class=\"informative-flag\">I</a>:</b> <div><p>Encrypt Record Lifecycle Event - occurs when an agent causes the system to encode record entry content in a cipher.</p>\n<p>Reference: ISO 21089-2018, Section 15.26.</p>\n</div></span>\n \n\n \n\n \n <span id=\"requirements\"><b>Criteria <a href=\"https://hl7.org/fhir/versions.html#std-process\" title=\"Normative Content\" class=\"normative-flag\">N</a>:</b></span>\n \n <table id=\"statements\" class=\"grid dict\">\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.26#01</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL provide the ability to render encrypted Record Entry content based on a cipher.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.26#02</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHOULD</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHOULD maintain the original and all previous versions of the Record Entry, retaining each version instance without alteration.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.26#03</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHOULD</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHOULD capture a new uniquely identifiable version of the Record Entry, incorporating encrypted content.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n </table>\n</div>"
},
"url" : "http://hl7.org/ehrs/Requirements/EHRSFMR2.1-RI.1.1.26",
"version" : "0.14.0",
"name" : "RI_1_1_26_Encrypt_Record_Entries",
"title" : "RI.1.1.26 Encrypt Record Entries (Function)",
"status" : "active",
"date" : "2024-06-01T08:34:10+00:00",
"publisher" : "EHR WG",
"contact" : [
{
"telecom" : [
{
"system" : "url",
"value" : "http://www.hl7.org/Special/committees/ehr"
}
]
}
],
"description" : "Encrypt Record Entries (1 or more instances)",
"purpose" : "Encrypt Record Lifecycle Event - occurs when an agent causes the system to encode record entry content in a cipher. \n\nReference: ISO 21089-2018, Section 15.26.",
"statement" : [
{
"extension" : [
{
"url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
"valueBoolean" : false
}
],
"key" : "EHRSFMR2.1-RI.1.1.26-01",
"label" : "RI.1.1.26#01",
"conformance" : [
"SHALL"
],
"conditionality" : false,
"requirement" : "The system SHALL provide the ability to render encrypted Record Entry content based on a cipher."
},
{
"extension" : [
{
"url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
"valueBoolean" : false
}
],
"key" : "EHRSFMR2.1-RI.1.1.26-02",
"label" : "RI.1.1.26#02",
"conformance" : [
"SHOULD"
],
"conditionality" : false,
"requirement" : "The system SHOULD maintain the original and all previous versions of the Record Entry, retaining each version instance without alteration."
},
{
"extension" : [
{
"url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
"valueBoolean" : false
}
],
"key" : "EHRSFMR2.1-RI.1.1.26-03",
"label" : "RI.1.1.26#03",
"conformance" : [
"SHOULD"
],
"conditionality" : false,
"requirement" : "The system SHOULD capture a new uniquely identifiable version of the Record Entry, incorporating encrypted content."
}
]
}