ISO/HL7 10781 - Electronic Health Record System Functional Model, Release 2.1 - Local Development build (v0.14.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions
Active as of 2024-06-01 |
@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .
# - resource -------------------------------------------------------------------
a fhir:Requirements ;
fhir:nodeRole fhir:treeRoot ;
fhir:id [ fhir:v "EHRSFMR2.1-RI.1.1.26.1"] ; #
fhir:meta [
( fhir:profile [
fhir:v "http://hl7.org/ehrs/StructureDefinition/FMFunction"^^xsd:anyURI ;
fhir:link <http://hl7.org/ehrs/StructureDefinition/FMFunction> ] )
] ; #
fhir:text [
fhir:status [ fhir:v "extensions" ] ;
fhir:div "<div xmlns=\"http://www.w3.org/1999/xhtml\">\n <span id=\"description\"><b>Statement <a href=\"https://hl7.org/fhir/versions.html#std-process\" title=\"Normative Content\" class=\"normative-flag\">N</a>:</b> <div><p>Maintain Evidence of Record Entry Encryption Event</p>\n</div></span>\n\n \n <span id=\"purpose\"><b>Description <a href=\"https://hl7.org/fhir/versions.html#std-process\" title=\"Informative Content\" class=\"informative-flag\">I</a>:</b> <div><p>Evidence of Record Entry Encryption Event includes key metadata, ensures health record integrity (and trust) and enables record audit.</p>\n</div></span>\n \n\n \n\n \n <span id=\"requirements\"><b>Criteria <a href=\"https://hl7.org/fhir/versions.html#std-process\" title=\"Normative Content\" class=\"normative-flag\">N</a>:</b></span>\n \n <table id=\"statements\" class=\"grid dict\">\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.26.1#01</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL audit each occurrence when Record Entry content is encrypted.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.26.1#02</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL capture identity of the organization where Record Entry content is encrypted.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.26.1#03</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL capture identity of the patient who is subject of encrypted Record Entry content.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.26.1#04</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>IF a user initiated a Record Entry content encryption, THEN the system SHALL capture identity of the user initiating Record Entry content encryption.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.26.1#05</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL capture identity of the system application which encrypted Record Entry content.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.26.1#06</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL capture the type of Record Event trigger (i.e., encryption).</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.26.1#07</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL capture the date and time Record Entry content is encrypted.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.26.1#08</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL capture identity of the location (i.e., network address) where Record Entry content is encrypted.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.26.1#09</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>MAY</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>IF a user initiated a Record Entry encryption, THEN the system MAY capture the rationale for encrypting Record Entry content.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.26.1#10</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL capture a sequence identifier for encrypted Record Entry content.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.26.1#11</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHOULD</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHOULD capture the identifier and version of Encryption Tools used for each encrypted Record Entry.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.26.1#12</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHOULD</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHOULD capture a reference (e.g., link, pointer) to pre-encrypted data for each Record Entry encryption.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n </table>\n</div>"
] ; #
fhir:url [ fhir:v "http://hl7.org/ehrs/Requirements/EHRSFMR2.1-RI.1.1.26.1"^^xsd:anyURI] ; #
fhir:version [ fhir:v "0.14.0"] ; #
fhir:name [ fhir:v "RI_1_1_26_1_Evidence_of_Record_Entry_Encryption_Event"] ; #
fhir:title [ fhir:v "RI.1.1.26.1 Evidence of Record Entry Encryption Event (Function)"] ; #
fhir:status [ fhir:v "active"] ; #
fhir:date [ fhir:v "2024-06-01T08:34:10+00:00"^^xsd:dateTime] ; #
fhir:publisher [ fhir:v "EHR WG"] ; #
fhir:contact ( [
( fhir:telecom [
fhir:system [ fhir:v "url" ] ;
fhir:value [ fhir:v "http://www.hl7.org/Special/committees/ehr" ] ] )
] ) ; #
fhir:description [ fhir:v "Maintain Evidence of Record Entry Encryption Event"] ; #
fhir:purpose [ fhir:v "Evidence of Record Entry Encryption Event includes key metadata, ensures health record integrity (and trust) and enables record audit."] ; #
fhir:statement ( [
( fhir:extension [
fhir:url [ fhir:v "http://hl7.org/ehrs/StructureDefinition/requirements-dependent"^^xsd:anyURI ] ;
fhir:value [ fhir:v "false"^^xsd:boolean ] ] ) ;
fhir:key [ fhir:v "EHRSFMR2.1-RI.1.1.26.1-01" ] ;
fhir:label [ fhir:v "RI.1.1.26.1#01" ] ;
( fhir:conformance [ fhir:v "SHALL" ] ) ;
fhir:conditionality [ fhir:v "false"^^xsd:boolean ] ;
fhir:requirement [ fhir:v "The system SHALL audit each occurrence when Record Entry content is encrypted." ]
] [
( fhir:extension [
fhir:url [ fhir:v "http://hl7.org/ehrs/StructureDefinition/requirements-dependent"^^xsd:anyURI ] ;
fhir:value [ fhir:v "false"^^xsd:boolean ] ] ) ;
fhir:key [ fhir:v "EHRSFMR2.1-RI.1.1.26.1-02" ] ;
fhir:label [ fhir:v "RI.1.1.26.1#02" ] ;
( fhir:conformance [ fhir:v "SHALL" ] ) ;
fhir:conditionality [ fhir:v "false"^^xsd:boolean ] ;
fhir:requirement [ fhir:v "The system SHALL capture identity of the organization where Record Entry content is encrypted." ]
] [
( fhir:extension [
fhir:url [ fhir:v "http://hl7.org/ehrs/StructureDefinition/requirements-dependent"^^xsd:anyURI ] ;
fhir:value [ fhir:v "false"^^xsd:boolean ] ] ) ;
fhir:key [ fhir:v "EHRSFMR2.1-RI.1.1.26.1-03" ] ;
fhir:label [ fhir:v "RI.1.1.26.1#03" ] ;
( fhir:conformance [ fhir:v "SHALL" ] ) ;
fhir:conditionality [ fhir:v "false"^^xsd:boolean ] ;
fhir:requirement [ fhir:v "The system SHALL capture identity of the patient who is subject of encrypted Record Entry content." ]
] [
( fhir:extension [
fhir:url [ fhir:v "http://hl7.org/ehrs/StructureDefinition/requirements-dependent"^^xsd:anyURI ] ;
fhir:value [ fhir:v "false"^^xsd:boolean ] ] ) ;
fhir:key [ fhir:v "EHRSFMR2.1-RI.1.1.26.1-04" ] ;
fhir:label [ fhir:v "RI.1.1.26.1#04" ] ;
( fhir:conformance [ fhir:v "SHALL" ] ) ;
fhir:conditionality [ fhir:v "false"^^xsd:boolean ] ;
fhir:requirement [ fhir:v "IF a user initiated a Record Entry content encryption, THEN the system SHALL capture identity of the user initiating Record Entry content encryption." ]
] [
( fhir:extension [
fhir:url [ fhir:v "http://hl7.org/ehrs/StructureDefinition/requirements-dependent"^^xsd:anyURI ] ;
fhir:value [ fhir:v "false"^^xsd:boolean ] ] ) ;
fhir:key [ fhir:v "EHRSFMR2.1-RI.1.1.26.1-05" ] ;
fhir:label [ fhir:v "RI.1.1.26.1#05" ] ;
( fhir:conformance [ fhir:v "SHALL" ] ) ;
fhir:conditionality [ fhir:v "false"^^xsd:boolean ] ;
fhir:requirement [ fhir:v "The system SHALL capture identity of the system application which encrypted Record Entry content." ]
] [
( fhir:extension [
fhir:url [ fhir:v "http://hl7.org/ehrs/StructureDefinition/requirements-dependent"^^xsd:anyURI ] ;
fhir:value [ fhir:v "false"^^xsd:boolean ] ] ) ;
fhir:key [ fhir:v "EHRSFMR2.1-RI.1.1.26.1-06" ] ;
fhir:label [ fhir:v "RI.1.1.26.1#06" ] ;
( fhir:conformance [ fhir:v "SHALL" ] ) ;
fhir:conditionality [ fhir:v "false"^^xsd:boolean ] ;
fhir:requirement [ fhir:v "The system SHALL capture the type of Record Event trigger (i.e., encryption)." ]
] [
( fhir:extension [
fhir:url [ fhir:v "http://hl7.org/ehrs/StructureDefinition/requirements-dependent"^^xsd:anyURI ] ;
fhir:value [ fhir:v "false"^^xsd:boolean ] ] ) ;
fhir:key [ fhir:v "EHRSFMR2.1-RI.1.1.26.1-07" ] ;
fhir:label [ fhir:v "RI.1.1.26.1#07" ] ;
( fhir:conformance [ fhir:v "SHALL" ] ) ;
fhir:conditionality [ fhir:v "false"^^xsd:boolean ] ;
fhir:requirement [ fhir:v "The system SHALL capture the date and time Record Entry content is encrypted." ]
] [
( fhir:extension [
fhir:url [ fhir:v "http://hl7.org/ehrs/StructureDefinition/requirements-dependent"^^xsd:anyURI ] ;
fhir:value [ fhir:v "false"^^xsd:boolean ] ] ) ;
fhir:key [ fhir:v "EHRSFMR2.1-RI.1.1.26.1-08" ] ;
fhir:label [ fhir:v "RI.1.1.26.1#08" ] ;
( fhir:conformance [ fhir:v "SHALL" ] ) ;
fhir:conditionality [ fhir:v "false"^^xsd:boolean ] ;
fhir:requirement [ fhir:v "The system SHALL capture identity of the location (i.e., network address) where Record Entry content is encrypted." ]
] [
( fhir:extension [
fhir:url [ fhir:v "http://hl7.org/ehrs/StructureDefinition/requirements-dependent"^^xsd:anyURI ] ;
fhir:value [ fhir:v "false"^^xsd:boolean ] ] ) ;
fhir:key [ fhir:v "EHRSFMR2.1-RI.1.1.26.1-09" ] ;
fhir:label [ fhir:v "RI.1.1.26.1#09" ] ;
( fhir:conformance [ fhir:v "MAY" ] ) ;
fhir:conditionality [ fhir:v "false"^^xsd:boolean ] ;
fhir:requirement [ fhir:v "IF a user initiated a Record Entry encryption, THEN the system MAY capture the rationale for encrypting Record Entry content." ]
] [
( fhir:extension [
fhir:url [ fhir:v "http://hl7.org/ehrs/StructureDefinition/requirements-dependent"^^xsd:anyURI ] ;
fhir:value [ fhir:v "false"^^xsd:boolean ] ] ) ;
fhir:key [ fhir:v "EHRSFMR2.1-RI.1.1.26.1-10" ] ;
fhir:label [ fhir:v "RI.1.1.26.1#10" ] ;
( fhir:conformance [ fhir:v "SHALL" ] ) ;
fhir:conditionality [ fhir:v "false"^^xsd:boolean ] ;
fhir:requirement [ fhir:v "The system SHALL capture a sequence identifier for encrypted Record Entry content." ]
] [
( fhir:extension [
fhir:url [ fhir:v "http://hl7.org/ehrs/StructureDefinition/requirements-dependent"^^xsd:anyURI ] ;
fhir:value [ fhir:v "false"^^xsd:boolean ] ] ) ;
fhir:key [ fhir:v "EHRSFMR2.1-RI.1.1.26.1-11" ] ;
fhir:label [ fhir:v "RI.1.1.26.1#11" ] ;
( fhir:conformance [ fhir:v "SHOULD" ] ) ;
fhir:conditionality [ fhir:v "false"^^xsd:boolean ] ;
fhir:requirement [ fhir:v "The system SHOULD capture the identifier and version of Encryption Tools used for each encrypted Record Entry." ]
] [
( fhir:extension [
fhir:url [ fhir:v "http://hl7.org/ehrs/StructureDefinition/requirements-dependent"^^xsd:anyURI ] ;
fhir:value [ fhir:v "false"^^xsd:boolean ] ] ) ;
fhir:key [ fhir:v "EHRSFMR2.1-RI.1.1.26.1-12" ] ;
fhir:label [ fhir:v "RI.1.1.26.1#12" ] ;
( fhir:conformance [ fhir:v "SHOULD" ] ) ;
fhir:conditionality [ fhir:v "false"^^xsd:boolean ] ;
fhir:requirement [ fhir:v "The system SHOULD capture a reference (e.g., link, pointer) to pre-encrypted data for each Record Entry encryption." ]
] ) . #
IG © 2023 EHR WG. Package hl7.ehrsfmr21.base#0.14.0 based on FHIR 5.0.0. Generated 2024-06-01