Amend (Update) Record Entry (1 instance)
Occurs when an agent makes any change to record entry content currently residing in storage considered permanent (persistent).
Reference: ISO 21089-2018, Section 15.2.
RI.1.1.2#01 | SHALL |
The system SHALL provide the ability to update (amend) Record Entry content. |
RI.1.1.2#02 | SHALL |
The system SHALL maintain the original and all previously amended versions of the Record Entry, retaining each version instance without alteration. |
RI.1.1.2#03 | SHALL |
The system SHALL capture a new uniquely identifiable version of the Record Entry, incorporating amended content. |
RI.1.1.2#04 | SHALL |
The system SHALL capture the signature event (e.g., digital signature) of the amendment Author, binding signature to Record Entry content. |