| TI.8#01 | SHALL |
The system SHALL provide the ability to backup and recover PHR information according to scope of practice, organizational policy, and/or jurisdictional law. |
| TI.8#02 | SHALL |
The system SHALL provide the ability to backup and recover all database contents including programs and all software components necessary to permit a complete PHR to be recovered. (i.e., 'full' backup and recovery) |
| TI.8#03 | MAY |
The system MAY provide the ability to backup and recover PHR information using alternative backup methods in addition to a full backup/recovery (e.g., incremental, differential, reverse delta, or continuous). |
| TI.8#04 | MAY |
The system MAY provide the ability to backup PHR information according to a defined schedule of storage media rotation. |
| TI.8#05 | SHALL |
IF the PHR user requirements specify that the PHR system be available continuously, THEN the system SHALL provide the ability to backup PHR information concurrently with the normal operation of the PHR application. |
| TI.8#06 | SHOULD |
The system SHOULD provide the ability to backup PHR information to a remote location. |
| TI.8#07 | MAY |
The system MAY provide the ability to backup PHR information to more than one storage media (e.g., disk, tape, or cloud). |
| TI.8#08 | MAY |
The system MAY provide the ability to encrypt backup data. |