Personal Health Record System Functional Model, Release 2
0.1.0 - CI Build

Personal Health Record System Functional Model, Release 2 - Local Development build (v0.1.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions

Example Requirements: TI.2.1 Audit Triggers (Function)

Active as of 2024-01-31
TI.2.1#01 SHALL

The system SHALL audit key events, as specified in function [[TI.2.1]] (Audit Triggers) and child functions, according to scope of practice, organizational policy, and/or jurisdictional law.

TI.2.1#02 SHALL

The system SHALL capture key Audit Metadata at each Audit Trigger, as specified in [[TI.2.1]] (Audit Triggers) and child functions, according to scope of practice, organizational policy, and/or jurisdictional law.

TI.2.1#03 SHALL

The system SHALL capture an Audit Log Entry at each Audit Trigger as specified in [[TI.2.1]] (Audit Triggers) according to scope of practice, organizational policy, and/or jurisdictional law.

TI.2.1#04 SHALL

The system SHALL capture the current master clock time to establish valid record date and time metadata.

TI.2.1#05 MAY

The system MAY manage Audit Trigger logging using a common audit engine (e.g., using schema and transports such as specified in the Audit Log specification of IHE Audit Trails and Node Authentication (ATNA) Profile).