<Requirements xmlns="http://hl7.org/fhir">
  <id value="PHRSFMR2-TI.2.1.3.8"/>
  <meta>
    <profile value="http://hl7.org/ehrs/StructureDefinition/FMFunction"/>
  </meta>
  <text>
    <status value="extensions"/>
    <div xmlns="http://www.w3.org/1999/xhtml">
    <table id="statements" class="grid dict">
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>TI.2.1.3.8#01</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                <span>SHALL</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>The system SHALL audit each occurrence when a batch job is completed.</p>
</div></span>
                

                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>TI.2.1.3.8#02</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                <span>SHALL</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>The system SHALL capture identity of the organization.</p>
</div></span>
                

                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>TI.2.1.3.8#03</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                <span>SHALL</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>IF known, THEN the system SHALL capture identity of the user.</p>
</div></span>
                

                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>TI.2.1.3.8#04</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                <span>SHALL</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>The system SHALL capture identity of the system.</p>
</div></span>
                

                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>TI.2.1.3.8#05</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                <span>SHALL</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>The system SHALL capture the event initiating audit trigger.</p>
</div></span>
                

                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>TI.2.1.3.8#06</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                <span>SHALL</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>The system SHALL capture the date and time of the event initiating audit trigger.</p>
</div></span>
                

                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
                
                <span>TI.2.1.3.8#07</span>
                
            </td>
            <td style="padding-left: 4px;">
                
                <span>SHALL</span>
                
            </td>
            <td style="padding-left: 4px;" class="requirement">
                
                <span><div><p>The system SHALL capture identity of the location (i.e., network address).</p>
</div></span>
                

                
            </td>
        </tr>
        
    </table>
</div>
  </text>
  <url value="http://hl7.org/ehrs/Requirements/PHRSFMR2-TI.2.1.3.8"/>
  <version value="0.1.0"/>
  <name value="TI_2_1_3_8_Batch_Job_Completed_System_Audit_Trigger"/>
  <title
         value="TI.2.1.3.8 Batch Job Completed System Audit Trigger (Function)"/>
  <status value="active"/>
  <date value="2024-01-31T14:45:34+00:00"/>
  <publisher value="EHR WG"/>
  <contact>
    <telecom>
      <system value="url"/>
      <value value="http://www.hl7.org/Special/committees/ehr"/>
    </telecom>
  </contact>
  <description
               value="Capture batch job completed event, both routine and exceptional, including key metadata (who, what, when, where, why)."/>
  <statement>
    <key value="PHRSFMR2-TI.2.1.3.8-01"/>
    <label value="TI.2.1.3.8#01"/>
    <conformance value="SHALL"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHALL audit each occurrence when a batch job is completed."/>
  </statement>
  <statement>
    <key value="PHRSFMR2-TI.2.1.3.8-02"/>
    <label value="TI.2.1.3.8#02"/>
    <conformance value="SHALL"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHALL capture identity of the organization."/>
  </statement>
  <statement>
    <key value="PHRSFMR2-TI.2.1.3.8-03"/>
    <label value="TI.2.1.3.8#03"/>
    <conformance value="SHALL"/>
    <conditionality value="true"/>
    <requirement
                 value="IF known, THEN the system SHALL capture identity of the user."/>
  </statement>
  <statement>
    <key value="PHRSFMR2-TI.2.1.3.8-04"/>
    <label value="TI.2.1.3.8#04"/>
    <conformance value="SHALL"/>
    <conditionality value="false"/>
    <requirement value="The system SHALL capture identity of the system."/>
  </statement>
  <statement>
    <key value="PHRSFMR2-TI.2.1.3.8-05"/>
    <label value="TI.2.1.3.8#05"/>
    <conformance value="SHALL"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHALL capture the event initiating audit trigger."/>
  </statement>
  <statement>
    <key value="PHRSFMR2-TI.2.1.3.8-06"/>
    <label value="TI.2.1.3.8#06"/>
    <conformance value="SHALL"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHALL capture the date and time of the event initiating audit trigger."/>
  </statement>
  <statement>
    <key value="PHRSFMR2-TI.2.1.3.8-07"/>
    <label value="TI.2.1.3.8#07"/>
    <conformance value="SHALL"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHALL capture identity of the location (i.e., network address)."/>
  </statement>
</Requirements>