Personal Health Record System Functional Model, Release 2
0.1.0 - CI Build
Personal Health Record System Functional Model, Release 2 - Local Development build (v0.1.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions
| Active as of 2024-01-31 |
<Requirements xmlns="http://hl7.org/fhir">
<id value="PHRSFMR2-TI.2.1.3.14"/>
<meta>
<profile value="http://hl7.org/ehrs/StructureDefinition/FMFunction"/>
</meta>
<text>
<status value="extensions"/>
<div xmlns="http://www.w3.org/1999/xhtml">
<table id="statements" class="grid dict">
<tr>
<td style="padding-left: 4px;">
<span>TI.2.1.3.14#01</span>
</td>
<td style="padding-left: 4px;">
<span>SHALL</span>
</td>
<td style="padding-left: 4px;" class="requirement">
<span><div><p>The system SHALL audit each occurrence of a system maintenance event when PHR or clinical software is updated or re-configured.</p>
</div></span>
</td>
</tr>
<tr>
<td style="padding-left: 4px;">
<span>TI.2.1.3.14#02</span>
</td>
<td style="padding-left: 4px;">
<span>SHALL</span>
</td>
<td style="padding-left: 4px;" class="requirement">
<span><div><p>The system SHALL capture identity of the organization.</p>
</div></span>
</td>
</tr>
<tr>
<td style="padding-left: 4px;">
<span>TI.2.1.3.14#03</span>
</td>
<td style="padding-left: 4px;">
<span>SHALL</span>
</td>
<td style="padding-left: 4px;" class="requirement">
<span><div><p>IF known, THEN the system SHALL capture identity of the user.</p>
</div></span>
</td>
</tr>
<tr>
<td style="padding-left: 4px;">
<span>TI.2.1.3.14#04</span>
</td>
<td style="padding-left: 4px;">
<span>SHALL</span>
</td>
<td style="padding-left: 4px;" class="requirement">
<span><div><p>The system SHALL capture identity of the system.</p>
</div></span>
</td>
</tr>
<tr>
<td style="padding-left: 4px;">
<span>TI.2.1.3.14#05</span>
</td>
<td style="padding-left: 4px;">
<span>SHALL</span>
</td>
<td style="padding-left: 4px;" class="requirement">
<span><div><p>The system SHALL capture the event initiating audit trigger.</p>
</div></span>
</td>
</tr>
<tr>
<td style="padding-left: 4px;">
<span>TI.2.1.3.14#06</span>
</td>
<td style="padding-left: 4px;">
<span>SHALL</span>
</td>
<td style="padding-left: 4px;" class="requirement">
<span><div><p>The system SHALL capture the date and time of the event initiating audit trigger.</p>
</div></span>
</td>
</tr>
<tr>
<td style="padding-left: 4px;">
<span>TI.2.1.3.14#07</span>
</td>
<td style="padding-left: 4px;">
<span>SHALL</span>
</td>
<td style="padding-left: 4px;" class="requirement">
<span><div><p>The system SHALL capture identity of the location (i.e., network address).</p>
</div></span>
</td>
</tr>
</table>
</div>
</text>
<url value="http://hl7.org/ehrs/Requirements/PHRSFMR2-TI.2.1.3.14"/>
<version value="0.1.0"/>
<name
value="TI_2_1_3_14_System_Maintenance___PHR_or_Clinical_Software_System_Audit_Trigger"/>
<title
value="TI.2.1.3.14 System Maintenance - PHR or Clinical Software System Audit Trigger (Function)"/>
<status value="active"/>
<date value="2024-01-31T14:45:34+00:00"/>
<publisher value="EHR WG"/>
<contact>
<telecom>
<system value="url"/>
<value value="http://www.hl7.org/Special/committees/ehr"/>
</telecom>
</contact>
<description
value="Capture system maintenance - PHR or clinical software, both routine and exceptional, including key metadata (who, what, when, where, why)."/>
<statement>
<key value="PHRSFMR2-TI.2.1.3.14-01"/>
<label value="TI.2.1.3.14#01"/>
<conformance value="SHALL"/>
<conditionality value="false"/>
<requirement
value="The system SHALL audit each occurrence of a system maintenance event when PHR or clinical software is updated or re-configured."/>
</statement>
<statement>
<key value="PHRSFMR2-TI.2.1.3.14-02"/>
<label value="TI.2.1.3.14#02"/>
<conformance value="SHALL"/>
<conditionality value="false"/>
<requirement
value="The system SHALL capture identity of the organization."/>
</statement>
<statement>
<key value="PHRSFMR2-TI.2.1.3.14-03"/>
<label value="TI.2.1.3.14#03"/>
<conformance value="SHALL"/>
<conditionality value="true"/>
<requirement
value="IF known, THEN the system SHALL capture identity of the user."/>
</statement>
<statement>
<key value="PHRSFMR2-TI.2.1.3.14-04"/>
<label value="TI.2.1.3.14#04"/>
<conformance value="SHALL"/>
<conditionality value="false"/>
<requirement value="The system SHALL capture identity of the system."/>
</statement>
<statement>
<key value="PHRSFMR2-TI.2.1.3.14-05"/>
<label value="TI.2.1.3.14#05"/>
<conformance value="SHALL"/>
<conditionality value="false"/>
<requirement
value="The system SHALL capture the event initiating audit trigger."/>
</statement>
<statement>
<key value="PHRSFMR2-TI.2.1.3.14-06"/>
<label value="TI.2.1.3.14#06"/>
<conformance value="SHALL"/>
<conditionality value="false"/>
<requirement
value="The system SHALL capture the date and time of the event initiating audit trigger."/>
</statement>
<statement>
<key value="PHRSFMR2-TI.2.1.3.14-07"/>
<label value="TI.2.1.3.14#07"/>
<conformance value="SHALL"/>
<conditionality value="false"/>
<requirement
value="The system SHALL capture identity of the location (i.e., network address)."/>
</statement>
</Requirements>