Example Requirements: TI.2.1.2.3 User Authentication (System Prompt for Password Change) Security Audit Trigger (Function)

Active as of 2024-01-31
TI.2.1.2.3#01 SHALL

The system SHALL audit each occurrence of user authentication when user is prompted to change password.

TI.2.1.2.3#02 SHALL

The system SHALL capture identity of the organization.

TI.2.1.2.3#03 SHALL

IF known, THEN the system SHALL capture identity of the user.

TI.2.1.2.3#04 SHALL

The system SHALL capture the identity of the system.

TI.2.1.2.3#05 SHALL

The system SHALL capture the event initiating audit trigger.

TI.2.1.2.3#06 SHALL

The system SHALL capture the date and time of the event initiating audit trigger.

TI.2.1.2.3#07 SHALL

The system SHALL capture identity of the location (i.e., network address).

TI.2.1.2.3#08 SHALL

IF password change successful, THEN the system SHALL capture the new password.