Personal Health Record System Functional Model, Release 2
0.1.0 - CI Build
Personal Health Record System Functional Model, Release 2 - Local Development build (v0.1.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions
| Active as of 2024-01-31 |
{
"resourceType" : "Requirements",
"id" : "PHRSFMR2-RI.1.1.8",
"meta" : {
"profile" : [
🔗 "http://hl7.org/ehrs/StructureDefinition/FMFunction"
]
},
"text" : {
"status" : "extensions",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">\n <table id=\"statements\" class=\"grid dict\">\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.8#01</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n <span>SHOULD</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHOULD provide the ability to transmit Record Entry content to external systems, retaining original, unaltered content and signature bindings, Action and Record Entry provenance and metadata.</p>\n</div></span>\n \n\n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.8#02</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL provide the ability to transmit Record Entry extracts to external systems, including content, context, provenance and metadata.</p>\n</div></span>\n \n\n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.8#03</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL provide the ability to capture the identity of the patient or individual subject to whom Record Entry content was transmitted.</p>\n</div></span>\n \n\n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.8#04</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n <span>SHOULD</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>IF a specific recipient is known, THEN the system SHOULD transmit protected Record Entry content based on established permissions and according to scope of practice, organizational policy, and/or jurisdictional law.</p>\n</div></span>\n \n\n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.8#05</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n <span>SHOULD</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>IF known and explicit as to Record Entry content being transmitted, THEN the system SHOULD transmit corresponding authorizations and patient consent permissions.</p>\n</div></span>\n \n\n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.8#06</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL conform to function [[TI.1.6]] (Secure Data Exchange).</p>\n</div></span>\n \n\n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.8#07</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL provide the ability to extract Record Entry content prior to transmittal, conforming to function [[RI.1.1.13]] (Extract Record Entry Content).</p>\n</div></span>\n \n\n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.8#08</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL provide the ability to de-identify Record Entry content prior to transmittal, conforming to function [[RI.1.1.10]] (De-Identify Record Entries).</p>\n</div></span>\n \n\n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.8#09</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL provide the ability to transmit updates (new versions) of Record Entry Content to known recipients of prior versions according to scope of practice, organizational policy, and/or jurisdictional law.</p>\n</div></span>\n \n\n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>RI.1.1.8#10</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL provide the ability to transmit with each exchange the most recent or all versions of Record Entry Content according to scope of practice, organizational policy, and/or jurisdictional law.</p>\n</div></span>\n \n\n \n </td>\n </tr>\n \n </table>\n</div>"
},
"url" : "http://hl7.org/ehrs/Requirements/PHRSFMR2-RI.1.1.8",
"version" : "0.1.0",
"name" : "RI_1_1_8_Transmit_Record_Lifecycle_Event",
"title" : "RI.1.1.8 Transmit Record Lifecycle Event (Function)",
"status" : "active",
"date" : "2024-01-31T14:45:34+00:00",
"publisher" : "EHR WG",
"contact" : [
{
"telecom" : [
{
"system" : "url",
"value" : "http://www.hl7.org/Special/committees/ehr"
}
]
}
],
"description" : "Occurs when an agent causes the system to send record entry content from one (EHR/PHR/other) system to another. \r\n\r\nReference: ISO 21089-2018, Section 15.8.",
"statement" : [
{
"key" : "PHRSFMR2-RI.1.1.8-01",
"label" : "RI.1.1.8#01",
"conformance" : [
"SHOULD"
],
"conditionality" : false,
"requirement" : "The system SHOULD provide the ability to transmit Record Entry content to external systems, retaining original, unaltered content and signature bindings, Action and Record Entry provenance and metadata."
},
{
"key" : "PHRSFMR2-RI.1.1.8-02",
"label" : "RI.1.1.8#02",
"conformance" : [
"SHALL"
],
"conditionality" : false,
"requirement" : "The system SHALL provide the ability to transmit Record Entry extracts to external systems, including content, context, provenance and metadata."
},
{
"key" : "PHRSFMR2-RI.1.1.8-03",
"label" : "RI.1.1.8#03",
"conformance" : [
"SHALL"
],
"conditionality" : false,
"requirement" : "The system SHALL provide the ability to capture the identity of the patient or individual subject to whom Record Entry content was transmitted."
},
{
"key" : "PHRSFMR2-RI.1.1.8-04",
"label" : "RI.1.1.8#04",
"conformance" : [
"SHOULD"
],
"conditionality" : true,
"requirement" : "IF a specific recipient is known, THEN the system SHOULD transmit protected Record Entry content based on established permissions and according to scope of practice, organizational policy, and/or jurisdictional law."
},
{
"key" : "PHRSFMR2-RI.1.1.8-05",
"label" : "RI.1.1.8#05",
"conformance" : [
"SHOULD"
],
"conditionality" : true,
"requirement" : "IF known and explicit as to Record Entry content being transmitted, THEN the system SHOULD transmit corresponding authorizations and patient consent permissions."
},
{
"key" : "PHRSFMR2-RI.1.1.8-06",
"label" : "RI.1.1.8#06",
"conformance" : [
"SHALL"
],
"conditionality" : false,
"requirement" : "The system SHALL conform to function [[TI.1.6]] (Secure Data Exchange)."
},
{
"key" : "PHRSFMR2-RI.1.1.8-07",
"label" : "RI.1.1.8#07",
"conformance" : [
"SHALL"
],
"conditionality" : false,
"requirement" : "The system SHALL provide the ability to extract Record Entry content prior to transmittal, conforming to function [[RI.1.1.13]] (Extract Record Entry Content)."
},
{
"key" : "PHRSFMR2-RI.1.1.8-08",
"label" : "RI.1.1.8#08",
"conformance" : [
"SHALL"
],
"conditionality" : false,
"requirement" : "The system SHALL provide the ability to de-identify Record Entry content prior to transmittal, conforming to function [[RI.1.1.10]] (De-Identify Record Entries)."
},
{
"key" : "PHRSFMR2-RI.1.1.8-09",
"label" : "RI.1.1.8#09",
"conformance" : [
"SHALL"
],
"conditionality" : false,
"requirement" : "The system SHALL provide the ability to transmit updates (new versions) of Record Entry Content to known recipients of prior versions according to scope of practice, organizational policy, and/or jurisdictional law."
},
{
"key" : "PHRSFMR2-RI.1.1.8-10",
"label" : "RI.1.1.8#10",
"conformance" : [
"SHALL"
],
"conditionality" : false,
"requirement" : "The system SHALL provide the ability to transmit with each exchange the most recent or all versions of Record Entry Content according to scope of practice, organizational policy, and/or jurisdictional law."
}
]
}